SNR S2989G-24TX [46/553] Switch upgrade
S2989G-24TX Operation Manual
Chapter
1
Basic
Management
Configuration
1-31
Trap verification community string of usertrap).
The configuration on the switch is listed below:
Switch(config)#snmp-server host 2004:1:2:3::2 v1 usertrap
Switch(config)#snmp-server enable traps
1.2.4.6 SNMP Troubleshooting
When users configure the SNMP, the SNMP server may fail to run properly due to
physical connection failure and wrong configuration, etc. Users can troubleshoot the
problems by following the guide below:
Good condition of the physical connection.
Interface and datalink layer protocol is Up (use the “show interface” command), and
the connection between the switch and host can be verified by ping (use “ping”
command).
The switch enabled SNMP Agent server function (use “snmp-server” command)
Secure IP for NMS (use “snmp-server securityip” command) and community string
(use “snmp-server communitycommand) are correctly configured, as any of them
fails, SNMP will not be able to communicate with NMS properly.
If Trap function is required, remember to enable Trap (use “snmp-server enable traps”
command). And remember to properly configure the target host IP address and
community string for Trap (use “snmp-server host” command) to ensure Trap
message can be sent to the specified host.
If RMON function is required, RMON must be enabled first (use “rmon enable”
command).
Use “show snmp” command to verify sent and received SNMP messages; Use “show
snmp status” command to verify SNMP configuration information; Use “debug snmp
packet” to enable SNMP debugging function and verify debug information.
If users still can’t solve the SNMP problems, Please contact our technical and service
center.
1.2.5
Switch Upgrade
Switch provides two ways for switch upgrade: BootROM upgrade and the TFTP/FTP
upgrade under Shell.
1.2.5.1 Switch System Files
The system files includes system image file and boot file. The updating of the switch
is to update the two files by overwrite the old files with the new ones.