S2989G-24TX Operation Manual
Chapter 7 Reliability Configuration
7-31
Figure 7-13 ULSM typical example
The above topology is the typical application environment which is used by ULSM
and ULPP protocol.
ULSM is used to process the port state synchronization, its independent running is
useless, so it usually associates with ULPP protocol to use. In the topology, SwitchA
enables ULPP protocol, it is used to switch the uplink. SwitchB and SwitchC enable ULSM
protocol to monitor whether the uplink is down. If it is down, then ULSM will execute the
down operation for the downlink port to shutdown it, so ULPP protocol of Swtich A
executes the relative operation of the uplink switchover.
SwitchA configuration task list:
Switch(Config)#spanning-tree mst configuration
Switch(Config-Mstp-Region)#instance 1 vlan 1
Switch(Config-Mstp-Region)#exit
Switch(Config)#ulpp group 1
Switch(ulpp-group-1)#protect vlan-reference-instance 1
Switch(ulpp-group-1)#exit
Switch(Config)#interface ethernet 1/0/1
Switch(config-If-Ethernet1/0/1)# ulpp group 1 master
Switch(config-If-Ethernet1/0/1)#exit
Switch(Config)#interface Ethernet 1/0/2
Switch(config-If-Ethernet1/0/2)# ulpp group 1 slave
Switch(config-If-Ethernet1/0/2)#exit
SwitchB configuration task list:
Switch(Config)#ulsm group 1
Switch(Config)#interface ethernet 1/0/1
SwitchD
E1/0/3
E1/0/4
SwitchB E1/0/1
E1/0/1
E1/0/2
SwitchA