Luxstahl MARCO Maxibrew-Twin [6/8] Note two flash and six flash error sequences will be displayed if there is low water pressure please check that there is water pressure and that the water stop valve...

Luxstahl MARCO Maxibrew-Twin [6/8] Note two flash and six flash error sequences will be displayed if there is low water pressure please check that there is water pressure and that the water stop valve...
1900064 REV.2 Page 6 of 8
TROUBLESHOOTING:
The Marco Qwikbrew 2 Twin uses an electronic diagnostic system to help determine faults.
If an error is detected a sequence of flashes is displayed through the POWER light. This
sequence is repeated (cycled) until:
1. The problem is rectified by a service agent, or
2. In the case of the 6 flash cycle the machine senses that normal operation has resumed,
and the flash sequence ceases.
The number of flashes in a cycle corresponds to the symptom in the table on the following
page.
Note: Two flash and six flash error sequences will be displayed if there is low water
pressure. Please check that there is water pressure and that the water stop -valve is
open before calling your service agent.
Status/Diagnostic light guide:
No of flashes
Symptom
Action required
2
Water level below elements.
Normal when machine first
fills.
Check water pressure, if this is OK -
call service agent.
3
Temperature sensor failure (o/c)
Call service agent
4
Water not heating
Call service agent
5
Temperature sensor failure (s/c)
Call service agent
6
Machine not filling
Check water pressure. If this is OK
and the machine has not returned to
normal operation after 15 min call
service agent

Похожие устройства