Kuppersbusch EDG 6550.0 BC [27/32] Technical characteristics

Kuppersbusch EDG 6550.0 BC [27/32] Technical characteristics
55
EN
Technical characteristics
Displays
Displays
Description
Display 1
Display 2
Display 3
Descaling
1
(clock)
Soft water.
2
---
Medium water.
3
---
Hard water.
---
Appliance must be descaled.
Flashing descaling starts.
0.5L
---
(clock)
Feed 0.6 litre descaling solution into the
water tank.
1.0L
---
(clock)
Feed 1 litre cold water into the water tank
for rinsing.
Water tank
---/(Temperature or
foodstuff group)
(Clock or time
setting)
Indication that water tank is missing.
---
(Clock)
The water tank must be removed, emptied
and reinserted.
Steam reduction
VAP
---
(Clock)
Indication that steam reduction process is
ongoing.
PUMP
---
(Clock)
Indication that cold water is entering the
boiler and hot water is being pumped to
the water tank.
FULL
---
(Clock)
The water tank must be removed, emptied
and reinserted.
System warnings
---
(Clock)
Damaged lamp.
---
(Clock)
Temperature in the PCB is too high.
(Clock)
Error in the pressure sensor.
(Clock)
Error in the oven’s temperature sensor.
(Clock)
Error in the boiler’s temperature sensor.
(Clock)
Error in the boiler’s level detectors.
(Clock)
Error in the water pump.