РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
МОРОЗИЛЬНЫЙ ЛАРЬ
Inoperation Whether the commercial showcase is plugged and
connected to power;
Low voltage;
Whether temperature control knob is in the work area;
Failure power or tripping circuit.
Odor Odorous foods should closely wrapped;
Whether foods are rotten;
Whether the interior shall be cleaned.
Long-term operation
of compressor
It is normal that commercial showcase operates for longer
time in summer when the ambient temperature is higher;
Do not put too much food in the commercial showcase at
one time;
Do not put foods until they are cooled;
Frequent opening of commercial showcase door;
Thick frost layer (defrost is needed).
Illuminating light does
not shine
Whether the commercial showcase is connected to power,
Whether the light is damaged.
The commercial
showcase door
can not be properly
closed
The commercial showcase door is stuck by food packages;
Too much food;
Unbalanced commercial showcase.
Loud noises Whether the floor is flat, whether the placement of
commercial showcase is stable;
Whether the commercial showcase parts are properly
placed.
Commercial
showcase enclosure
heat Condensation
The commercial showcase enclosure may emit heat during
operation specially in summer, this is caused by the radiation
of the condenser, and it is a normal phenomenon.
Condensation: condensation phenomenon will be detected
on the exterior surface of the commercial showcase when
the ambient humidity is high, this is a normal phenomenon,
and the condensation can be wiped away with a dry towel.
Airflow sound Buzz
Clatter
Refrigerant circulating in the refrigerant lines will produce
eruption of sound and grunts which is normal does not affect
the cooling effect.
Buzz will be generated by running compressor specially
when starting up or shutting down.
The solenoid valve or electric switch valve will clatter which
is a normal phenomenon and does not affect the operation.