Victoria Arduino Adonis 2 Gr [79/136] Cup warmer setpoint xxx c

Victoria Arduino Adonis 2 Gr [79/136] Cup warmer setpoint xxx c
77
EN
The message ON XX will begin to flash; use the W
V keys to change the cup warmer open time (from
0 to 60 min.).
Press ENTER to confirm and pass to the cup warm-
er OFF time (from 0 to 60 min.).
NOTE: Setting one of the two ON/OFF values to 0 will
automatically bypass the function.
When the cup warmer is programmed, the
button will flash slowly.
Press the ENTER key to pass to the next page.
Single temperature
The display will read:
Using the WV keys, it is possible to increase or
reduce the temperature within a certain range [40°C
÷ 80°C] / [104°F ÷ 176°F].
Press ENTER to confirm and pass to the next step.
Press RESET to return to the previous page without
confirming.
Double Temperature
The display will read:
Using the WV keys, it is possible to increase or
reduce the temperature no.1 within a certain range
[40°C - 80°C] / [104°F - 176°F].
Press RESET to return to the previous page without
confirming.
Press ENTER to confirm and pass to the next step;
the display will read:
Using the WV keys, it is possible to increase or
reduce the temperature no.2 within a certain range
[40°C ÷ 80°C] / [104°F ÷ 176°F].
Press ENTER to confirm and pass to the next step.
Press RESET to return to the previous page without
confirming.
DATE/TIME PROGRAMMING
The display will read:
By pressing the ENTER key, the display will read for
example:
The times will start to flash on and off.
Vary the hours and the minutes by using the
key WV.
CUP-WARMER
SETPOINT xxx°C
CUP-WARMER ™
SETPOINT xx°C
CUP-WARMER ¡
SETPOINT XXX°C
DATE/HOUR
MONDAY 08:22
08- MAG-03