RME ADI-648 [28/32] Midi implementation chart adi 648

RME ADI-648 [28/32] Midi implementation chart adi 648
28
User's Guide ADI-648 © RME
15. MIDI Implementation Chart ADI-648
15.1 Basic SysEx Format
Value
Name
F0h SysEx header
00h 20h 0Dh MIDITEMP manufacturer ID
64h Model ID (ADI-648)
00h..7Eh, 7Fh Device ID. 7Fh = broadcast (all IDs)
mm Message type
nn Parameter number (see table 1)
oo Data byte
F7h EOX
15.2 Message Types
Value
Name
10h Request value
20h Set value
30h Value response
Request Value
Format: F0 00 20 0D 64 (dev ID) 10 F7
This string triggers a complete dump of all value response data bytes.
Value Response
After being triggered by receiving a request value command, device sends a string of all value
response data bytes. Message type is set to 30h.
Set Value
Sets any number of parameters.
nn / oo can be repeated freely.
15.3 MADI Input State – Redundancy Mode
The MADI input can be BNC or optical. When the ADI-648 enters Redundancy mode, it uses
the other input, although not chosen and signalled by the MADI input select byte. See below
table.
MADI Input Select MADI Input State Actual input in use
0 = BNC 0 = normal operation BNC
1 = Optical 0 = normal operation Optical
0 = BNC 1 = Redundancy mode Optical
1 = Optical 1 = Redundancy mode BNC