APart CHAMP-3D Руководство по эксплуатации онлайн [18/24] 776866

APart CHAMP-3D Руководство по эксплуатации онлайн [18/24] 776866
WWW.APART-AUDIO.COM
18
STORE:possiblecommands:GET,SET.BinaryvalueisONonly.Usethiscommandtostoreall
editedaudiorelatedparameters.Thestoreinstructionlookslikethis:“SETSTOREON”.
ECHO:possiblecommands:GET,SET.BinaryvaluesareON,OFF.Usethiscommandtoenable
ordisableECHOviaRS232.
LF:possiblecommands:GET,SET.BinaryvaluesareON,OFF.Usethisinstructiontoenableor
disableLineFeedviaRS232.
BS:possiblecommands:GET,SET.BinaryvaluesareON,OFF.Usethisinstructiontoenableor
disableBackspaceviaRS232.
VALFB:possiblecommands:GET,SET.BinaryvaluesareON,OFF.Usethisinstructionto
enableordisablevaluefeedbackviaRS232.
USRSTF:withthisinstructionyoucansettheuserstringfont.Thereare3fonttypesavailable.
Possiblecommandsare:SET,GET,possiblevaluesare:1,2,3.
USRSTR:Possiblecommandsare:SET,GET.Withthiscommandyoucanprogramtheuser
stringtextthatwillbeshownonthedisplay.Inordertochangethetext:“SETUSRSTRxxxxxxxx”.
Themaximumnumberofcharactersdependsonthefonttype(1,2,3)andcharacterwidth.The
maximumis16ASCIIcharacters.Thetextwillbeautomaticallystoredinmemory.Theuserstring
iscasesensitive.
INFO:possiblecommand:GET.UsethisinstructiontogetstatusinformationviaRS232.
SERIAL:possiblecommand:GET.Usethisinstructiontogettheserialnumberfromtheunit.
HWVRSN:possiblecommand:GET.Usethisinstructiontogetthehardwareversion.
SWVRSN:possiblecommand:GET.Usethisinstructiontogetthesoftwareversion.
RESTORE:possiblecommand:SET.BinaryvalueON.Usetheinstruction“SETRESTOREON”
torestorethefactorysettings.Alluserdefinedsettingssuchasequalizerandcrossoversettings
willbeoverwrittenwiththefactorydefaultsettings.Theunitwillautomaticallyshutdownand
restartwiththemasterlevelat-∞.Thestandardpasswordtounlocktheunitisthis:“1234”
(withoutthebrackets).Weadviseyoutochangethispasswordtoalessobviouspassword,in
casethelockfunctionisrequiredofcourse.
STANDBY:possiblecommands:SET.BinaryvalueONorOFF.Aninstructioncouldlooklike
this:“SETSTANDBYON”,inthiscasetheunitwillgointostandbymode,currentconsumption
willbeminimal.Itisalsopossibletorequestthepowerstatusbysendingthe
“GETSTANDBY”command.
Скачать