AMERICAN DJ Zipper [2/14] Caution
![AMERICAN DJ Zipper [2/14] Caution](/views2/2009552/page2/bg2.png)
ADJ Products, LLC - www.adj.com - Zipper Instruction Manual Page 3ADJ Products, LLC - www.adj.com - Zipper Instruction Manual Page 2
• 3 DMX Modes: 1 Channel, 3 Channel, and 11 Channel
• 3 Operating Modes - Sound Active, Show Mode, & DMX Control
• Internal Microphone
• Digital Display for Address and Function Setting
• 16 Preprogrammed Shows
• Power Cord Daisy Chain (See page 21)
• UC IR Compatiable (Sold Separately)
Zipper Features
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures
warranty. In the unlikely event your unit may require service please
contact ADJ Products, LLC.
During operation the housing may become extremely hot. Avoid touch-
ing the unit with bare hands while in use.
ADJ Products, LLC will not accept any liability for any resulting dam-
ages caused by the non-observance of this manual or any unauthor-
ized modication to this unit.
Zipper Handling Precautions
Zipper Warranty Registration
The Zipper carries a 2 year (730 days) limited warranty. Please fill out
the enclosed warranty card to validate your purchase and warranty.
You may also register your product online at www. americandj.com.
All returned service items whether under warranty or not, must be
freight pre-paid and accompany a return authorization (R.A.) number.
If the unit is under warranty you must provide a copy of your proof of
purchase invoice. Please contact ADJ customer support for a R.A.
number.
To optimize the performance of this product, please read these
operating instructions carefully to familiarize yourself with the basic
operations of this unit. These instructions contain important safety
information regarding the use and maintenance of this unit. Please
keep this manual with the unit, for future reference.
Zipper General Instructions
Zipper General Information
Unpacking: Thank you for purchasing the Zipper by ADJ Products,
LLC. Every Zipper has been thoroughly tested and has been shipped
in perfect operating condition. Carefully check the shipping carton for
damage that may have occurred during shipping. If the carton appears
to be damaged, carefully inspect your xture for any damage and be
sure all equipment necessary to operate the unit has arrived intact. In
the event damage has been found or parts are missing, please contact
our toll free customer support number for further instructions. Please
do not return this unit to your dealer without contacting customer sup-
port rst.
Introduction: The Zipper is a DMX intelligent LED quad barrel roller.
The Zipper has three operating modes; a sound active, show mode,
DMX controlled. The Zipper has 3 DMX mode; 1 channel mode, 3
channel mode, and 11 channel mode. The Zipper can operate as a
stand alone fixture or in a Master/Slave configuration. For best results
use fog or special effects smoke to enhance the beams projections.
Customer Support: ADJ Products, LLC provides a toll free cus-
tomer support line, to provide help and to answer any question should
you encounter problems during your set up or initial operation. You
may also visit us on the web at www.adj.com for any comments or
suggestions. Service Hours are Monday through Friday 8:00 a.m. to
4:30 p.m. Pacic Standard Time.
Voice: (800) 322-6337
Fax: (323) 582-2941
E-mail: support@americandj.com
To purchase parts online visit http://parts.americandj.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
Содержание
- User instructions 1
- Zipper 1
- Caution 2
- Customer support 2
- Introduction 2
- Unpacking 2
- Warning 2
- Dmx 512 3
- Power supply 3
- Be sure to follow figures two and three when making your own cables do not use the ground lug on the xlr connector do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the xlr s outer casing grounding the shield could cause a short circuit and erratic behavior 4
- Chained and cannot be split 4
- Conductor 5 pin xlr male in 3 pin xlr female out 4
- Data compliment signal 4
- Data true signal 4
- Ground shield 4
- Not used 4
- Notice 4
- Pin 4 do not use 4
- Pin 5 do not use 4
- Pin xlr dmx connectors 4
- Pin xlr to 5 pin xlr conversion 4
- Some manufactures use 5 pin dmx 512 data cables for data transmission in place of 3 pin 5 pin dmx fixtures may be implemented in a 3 pin dmx line when inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores the chart below details a proper cable conversion 4
- Special note line termination 4
- When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behavior a terminator is a 110 120 ohm 1 4 watt resistor which is con nected between pins 2 and 3 of a male xlr connector data and data this unit is inserted in the female xlr connector of the last unit in your daisy chain to terminate the line using a cable terminator adj part number z dmx t will decrease the possibilities of erratic behavior 4
- Zipper set up 4
- Shnd sh 0 sh1 6
- Master slave configuration 8
- Operating modes the zipper can operate in three different modes in each mode you can run the fixture as a stand alone fixture or in a master slave confiugration this next section will detail the differences in the operating modes 8
- Show mode 8
- Sound active mode 8
- Universal dmx control 8
- Channel value function 9
- Shows 0 7 blackout 8 22 show 1 23 37 show 2 38 52 show 3 53 67 show 4 68 82 show 5 83 97 show 6 98 112 show 7 113 127 show 8 128 142 show 9 143 157 show 10 158 172 show 11 173 187 show 12 188 202 show 13 203 217 show 14 218 232 show 15 233 247 show 16 248 255 sound active shows 1 16 9
- Channel value function 10
- Pan tilt movements 0 7 0 degrees 8 22 movement 1 23 37 movement 2 38 52 movement 3 53 67 movement 4 68 82 movement 5 83 97 movement 6 98 112 movement 7 113 127 movement 8 128 142 movement 9 143 157 movement 10 158 172 movement 11 173 187 movement 12 188 202 movement 13 203 217 movement 14 218 232 movement 15 233 247 movement 16 248 255 sound active movement 1 16 2 dimmer 0 255 0 100 3 strobing 0 7 off 8 15 open 16 131 strobing slow fast 132 139 open 140 181 pulse effect slow fast fast close slow open 182 189 open 190 231 pulse effect slow fast slow close fast open 232 239 open 240 247 sound active strobing 248 255 open 10
- Channel value function 11
- Inno spot 700 11
- Photometrics diagram 11
- R b 16r 11
- Radiance beam 2r pro 11
- Radiance beam 5r 11
- Strobe 190 231 fast open slow close 232 239 open 240 247 sound active strobe 248 255 open 11 dimmer mode 0 20 standard 21 40 stage 41 60 tv 61 80 architectural 81 100 theatre 101 255 default dimmer setting 11
- Tvl1000 ii 11
- With this feature you can connect the fixtures to one another using the iec input and output sockets the quantity that can be connected is 10 fixtures maximum for 120v and 18 fixtures maxi mum for 240v after the maximum fixtures has been reached you will need to use a new power outlet they must be the same fix tures do not mix fixtures 11
- Xp 15r sz 11
- Xp 5r beam 11
- Zipper 11 channel mode dmx traits values 11
- Zipper dimmer curve chart 11
- Zipper photometric chart 11
- Zipper power cord daisy chain 11
- Adj products llc www adj com zipper instruction manual page 22 12
- Adj products llc www adj com zipper instruction manual page 23 12
- Always be sure to dry all parts completely before plugging the unit back in 12
- Be sure the external fuse has not blown the fuse is located on the bottom panel of the unit 12
- Be sure the fuse holder is completely and properly seated unit does not respond to sound 12
- Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 12
- Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew in heavy club use we recommend cleaning on a monthly basis periodic cleaning will ensure longevity and crisp out put 1 use normal glass cleaner and a soft cloth to wipe down the out side casing 12
- Fixture cleaning 12
- Locate the fuse holder is located at the rear of unit next to the power cord using a phillips head screwdriver remove the fuse holder remove the used fuse and replace with a matching fuse insert the fuse holder and fuse into the unit and secure the fuse holder 12
- Low frequencies bass should cause the unit to react to sound tapping on the microphone quiet or high pitched sounds may 12
- No light output from the unit 12
- Not activate the unit not activate the unit 12
- Trouble shooting listed below are a few common problems that you may encounter with solutions 12
- Use a brush to wipe down the cooling vents and fan grill 3 clean the external optics with glass cleaner and a soft cloth every 20 days 12
- Zipper cleaning 12
- Zipper fuse replacement 12
- Zipper trouble shooting 12
- Zipper warranty 12
- A d j supply europe b v 14
- Adj products llc 14
- Auto sensing voltage 14
- Ew kerkrade 14
- Junostraat 2 14
- Model zipper 14
- Netherlands 14
- Please note 14
- S eastern ave los angeles ca 90040 usa 14
- Service adjgroup eu www adj eu 14
- Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 14
- Tel 31 45 546 85 00 fax 31 45 546 85 99 14
- Tel 323 582 2650 fax 323 725 6100 14
- This fixture contains a automatic volt age switch which will auto sense the voltage when it is plugged into the power source 14
- Web www adj com e mail info americandj com 14
Похожие устройства
- AMERICAN DJ Vizi BSW300 Руководство по эксплуатации
- AMERICAN DJ Spherion WH LED Руководство по эксплуатации
- AMERICAN DJ Sparkle LED 3W Руководство по эксплуатации
- AMERICAN DJ Saturn TriLED SYS Руководство по эксплуатации
- AMERICAN DJ Revo Sweep Руководство по эксплуатации
- AMERICAN DJ Stinger Gobo Руководство по эксплуатации
- Arthur Forty U-9900B (UHF) Руководство по эксплуатации
- APart SDQ5PIR-BL Руководство по эксплуатации
- APart PMR4000RMKII Руководство по эксплуатации
- APart SDQ5PIR-W Руководство по эксплуатации
- APart OVO8-W Руководство по эксплуатации
- APart OVO8P-W Руководство по эксплуатации
- APart OVO8T-BL Руководство по эксплуатации
- American Audio VLP1500 Руководство по эксплуатации
- AMC HQ 10EN Руководство по эксплуатации
- ASHLY TRA-2150 Руководство по эксплуатации
- AMC HQ 15EN Руководство по эксплуатации
- ASHLY MX-508 Руководство по эксплуатации
- ASHLY MX-206 Руководство по эксплуатации
- ASHLY TRA-2075 Руководство по эксплуатации