Lock/unlock
In the non locked state, press and hold the "TEMP SELECT" for 3 seconds to enter the
locking state.
The unlock icon goes out and the lock buzzer sounds.
In the locked state, press and hold the "TEMP SELECT" for 3 seconds to enter the non
locking state.
The unlock icon lights up, the blue light bar lights up from the central axis to both sides,
and the unlocking beep sounds.
After 30 seconds of no operation, it will automatically enter the locking state, and the lock
buzzer will sound at the same time.
In addition to the alarm tone release operation can also be carried out in the locked state,
other operations must be carried out in the non locked state.
If it is operated in the locked state, an error beep will be given.
The light bar is in blue flashing state when the error is prompted.
Temperature setting
Temperature setting of refrigerating chamber
Press the "TEMP SELECT" to select the refrigeration temperature zone, and then press the
"+" and "-" button to adjust the temperature of the . Each time therefrigerating chamber
"-" key is pressed, the temperature will drop by 1 ,when the temperature reaches 2 ,
press the "-" button again will set the refrigeration chamber at 8 ; press the "+" button
once, the temperature will increase by 1 , and press the "+" button again when the
temperature reaches 8 will set the refrigeration chamber at 2 .
The setting range of is 2 ~ 8 ; the refrigerating chamber
The setting will take effect after locking.
Setting of variable chamber
Press the "TEMP SELECT" to select the temperature zone of the variable chamber, and then
press the "+" "-" button to adjust the variable chamber.
Each time the "+" key is pressed, it shifts up once; Each time the "-" key is pressed, it will
switch downward once; cycle according to the following way:
.-> -> ->
After locking the establishment takes effect.
Temperature setting of freezing chamber
Press the "TEMP SELECT" to select the freezing chamber, and then press the "+" and "-" keys
to adjust the temperature of the freezing chamber.
Each time the "- key is pressed, the temperature drops by 1 .
When the temperature reaches - 24 ,press the "+" button once again, the freezing
chamber is set to - 16 ; each time the "+" button is pressed once, the temperature
increases by 1 ; when the temperature reaches - 16 , press the "+" button again,the
freezing chamber will set to - 24℃.
The setting range of cold storage room is - 16 ~ - 24 ,the setting will take
effect after locking.