Aqara JY-GZ-03AQ [10/38] Fire alarm

Aqara JY-GZ-03AQ [10/38] Fire alarm
1.In the normal working status of the detector, hold down the
silence/self-test button for more than 3 seconds to confirm that the
indicator flashes red, yellow and green in turn, with three beeps of
the buzzer, which indicates that the self-test is normal.
2.Press and hold the button until the indicator and buzzer repeat the
above sound and light signals with a pause every three seconds, and
then release.
3. A monthly self-test on the detector is recommended. Contact the
aer-sales service immediately in case of any faults.
Self-test
1.Smoke detected
When the detector works normally and detects that the smoke
concentration is at or above the configured threshold value, the
indicator keeps flashing red once per second, and the buzzer sounds
loudly, with one beep per second and a pause every three beeps.
2. In case of a fire
Please take immediate and effective measures, such as using fire
extinguishing facilities, calling the fire alarm.
Fire alarm