Liebherr WTes 5972-22 Vinidor [4/16] Description of the appliance

Liebherr WTes 5972-22 Vinidor [4/16] Description of the appliance
18
Description of the appliance
Activated charcoal lter
Adjustable-height feet
Operating and control elements
Type plate
Lock
Interior light
(LED light strip)
Activated charcoal lter
Interior light
(LED light strip)
Pull-out shelves
Pull-out shelves
Saving energy
- Always ensure good ventilation. Do not cover ventilation open-
ings or grille.
- Always keep fan slits clear.
- Avoid positioning the appliance in direct sunlight or near cookers,
radiators or similar sources of heat.
- The energy consumption depends on the installation conditions,
e.g. the ambient temperature.
- Keep the time the appliance is open to a minimum.
Accumulated dust increases the energy consumption:
- Once a year, dust the refrigerating unit together with the metal
grid of the heat exchanger at the back of the appliance.
Climate rating
The climate rating indicates the room
temperature at which the appliance may
be operated in order to achieve full refrig-
eration performance.
The climate rating is indicated on the
type plate.
The position of the type plate is shown in the section entitled
Description of the appliance.
Climate rating Room temperature
SN +10°C to +32°C
N +16°C to +32°C
ST +16°C to +38°C
T +16°C to +43°C
SN-ST +10°C to +38°C
SN-T +10°C to +43°C
Do not operate the appliance outside the
specied room temperature range.
Setting up
Avoid positioning the appliance in direct sunlight or near cookers,
radiators and similar sources of heat.
The floor on which the appliance stands should be horizontal
and level.Compensate for uneven floors with the adjustable feet.
Standard EN 378 specifies that the room in which you install
your appliance must have a volume of 1 m
3
per 8 g of R 600a
refrigerant used in the appliance, so as to avoid the formation of
inflammable gas/air mixtures in the room where the appliance is
located in the event of a leak in the refrigerant circuit. The quantity
of refrigerant used in your appliance is indicated on the type plate
on the inside of the appliance.
Always install the appliance directly against the wall.
To ensure that the stated energy con-
sumption is achieved, the wall spacers
supplied with the appliance must be
used. This increases the depth of the
appliance by approx. 35 mm.
The appliance is fully operational even
if the spacers are not used. It does,
however, have a slightly higher energy
consumption.
Fit the spacers to the back of
the appliance on the left and
right at the top.