Centek CT-5110 [15/28] Display select the desired value 1 2 4 or 8 hours the corresponding value

Centek CT-5110 [15/28] Display select the desired value 1 2 4 or 8 hours the corresponding value
15
«ГИГРОСТАТ» (HYGROSTAT) Button (Humidity Level Adjustment)
Press the HYGROSTST button to set the desired air humidity in the room. The
adjustment values range from 45 to 90 % with a 5 % increment. After the
humidity value is set the numeric indicator will flash for 3 seconds, then the
appliance will automatically maintain the set humidity level; the current air
humidity level will be displayed. In order to reset the humidity level setting
press the HYGROSTAT button once again and select the 90 % value.
«УВЛАЖНЕНИЕ» (HUMIDIFY) Button (Vapor Discharge Output Adjustment)
In order to change the vapor discharge intensity press the HUMIDIFY several
times: 1 - low, 2 - medium, 3 – high vapor output level. The corresponding
numeric value will appear on the display.
TIMER Button (Timer Setup)
To set the timer press the TIMER button; the indicator will appear on the
display. Select the desired value: 1, 2, 4 or 8 hours. The corresponding value
will appear on the display. When the set time period elapses the appliance
will switch to the standby mode.
Automatic Low Water Shutdown Function
The appliance is equipped with a water level sensor (4). When the water level
in the tank is low the appliance will stop discharging vapor, an audio signal will
be emitted and the symbol will appear on the display. Turn the appliance
off and refill the tank with water.
5. MAINTENANCE
Always turn the appliance off before cleaning. Hard water causes scale on the
sprinkler and in the process chamber. This may lead to humidifier malfunctions
and exterior deterioration. In order to prevent the formation of scale:
- use boiled, filtered or distilled water;
- clean the process chamber every week;
- change the water in the tank more often.
WEEKLY MAINTENANCE
-
It is recommended to clean the water tank once every week. Wash the
process chamber using a liquid detergent. Then thoroughly rinse with pure
water.
-
Apply 5 to 10 drops of detergent on the sprinkler; wait for approx. 2 to 5
minutes. Use a soft brush to remove the deposits from the sprinkler surface.
-
You can use a kettle scaling agent as the detergent for cleaning the sprinkler.
- Do not submerge the appliance in water or any other liquids.
ATTENTION!
Microorganisms that may be present in the water or in the environment where
the humidifier is used or stored can accumulate in the water tank and, if
released into the air, pose very serious health risks. It is recommended to
clean the water tank and renew the water every 3 days.
STORAGE
-
Drain water from the tank and process chamber before putting the appliance
away for storage.
- Wipe the process chamber with a dry cloth.
-
Do not store the appliance with water in the tank and/or process chamber.
- Store appliance in a dry cool place, out of reach of children.
TROUBLESHOOTING
Problem Probable Cause Remedy
No vapor discharged
The unit is not properly
connected to power supply
Check power connection
The unit is not operational
Contact an authorized
service center
No water in the water tank
Fill the tank with water
Too little vapor
discharged
Impurities in the water
Clean the discharge nozzle
and fill the tank with clean
water
Unusual noise
Water level in the tank
too low or the appliance
is slanted
Fill water into the tank and
place the appliance on a
level flat surface
6. SPECIFICATIONS
- Nominal voltage: 220-240 V ~50/60 Hz
- Rated power supply: 25-30 W
- Water tank capacity: 3,8 l
- Up to 35 hours of continuous operation
- Humidification coverage: up to 30 sq.m
- Water consumption: 170-210 ml/h
7. DISPOSAL
Upon expiry of its service life the appliance can be disposed of separately
from ordinary domestic waste. You can turn it over to a specialized electric
and electronic appliance disposal and recycling centre.