Bosch GLM 100 C 0.601.072.700 [31/370] Maintenance and service

Bosch GLM 100 C 0.601.072.700 [31/370] Maintenance and service
30 | English
1 609 92A 25T | (19.2.16) Bosch Power Tools
The measuring tool monitors the correct
function for each measurement. When a de-
fect is determined, only the symbol shown
aside flashes in the display. In this case, or
when the above mentioned corrective
measures cannot correct an error, have the
measuring tool checked by an after-sales service agent for
Bosch power tools.
Maintenance and Service
Maintenance and Cleaning
Store and transport the measuring tool only in the supplied
protective pouch.
Keep the measuring tool clean at all times.
Do not immerse the measuring tool in water or other fluids.
Wipe off debris using a moist and soft cloth. Do not use any
cleaning agents or solvents.
Maintain the reception lens 17 in particular, with the same
care as required for eye glasses or the lens of a camera.
In case of repairs, send in the measuring tool packed in its
protective pouch 26.
After-sales Service and Application Service
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can al-
so be found under:
www.bosch-pt.com
Bosch’s application service team will gladly answer questions
concerning our products and their accessories.
In all correspondence and spare parts orders, please always
include the 10-digit article number given on the nameplate of
the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange
the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: boschservicecentre@bosch.com
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
City West
Dublin 24
Tel. Service: (01) 4666700
Fax: (01) 4666888
Data transmission via USB interface not possible
Software error Make sure that the software
runs correctly on your com-
puter or notebook. For fur-
ther information, please re-
fer to the Bosch website at
www.bosch-pt.com
Micro USB cable Check the proper and tight
seating of the micro USB
cable.
Check the micro USB cable
for damage.
Battery charge-control indicator (g) or prolonged charge
duration indication n on the display
Charge duration clearly too
long, as charging current too
low.
Only use the original Bosch
charger.
Measuring result not plausible
The target surface does not
reflect correctly (e.g. water,
glass).
Cover off the target surface
The laser beam outlet 18 or
the reception lens 17 are
covered.
Make sure that the laser
beam outlet 18 or the
reception lens 17 are unob-
structed
Wrong reference level set Select reference level that
corresponds to measure-
ment
Obstruction in path of laser
beam
Laser point must be com-
pletely on target surface.
The indication remains unchanged or the measuring tool
reacts unexpectedly after pressing a button
Software error Press the measuring button 2
and the button for clearing
the internal memory / On/Off
4 to reset the software.
Cause Corrective Measure
OBJ_DOKU-36146-003.fm Page 30 Friday, February 19, 2016 9:59 AM