Fubag OL 231/50 CM 2 [7/15] Start up and use

Содержание

Похожие устройства

fubag Operator s manual www fubag ru 2 Technical specifications MODEL OL 195 6 CM1 5 OL 195 24 CM1 5 OL 231 24 CM2 OL 231 50 CM2 1 1 1 1 1 5 1 5 Tank I 6 24 24 50 Pressure bar 8 8 8 8 180 180 230 230 3400 3400 2850 2850 220 50 220 50 220 50 220 50 495x270x490 600x260x580 600x255x590 830x325x655 9 5 11 16 33 Power kW Air displacement l min RPM Volt Hz Size mm Weight kg The manufacturer reserves himself the right to make the manual s content or function change without any preliminary notification of the users 3 Start up and use Fit the wheels and foot or the caster wheel for models that are fitted with this according to the instructions provided in the packaging For versions with fixed feet assemble the front bracket kit or the vibration dampers if furnished Check that the rating data match the effective characteristics of the system voltage and power Check for correspondence between the compressor plate data with the actual specifications of the electrical system A variation of 10 with respect of the rated value is allowed Insert the power plug in a suitable socket checking that the button of the pressure switch located on the compressor is in the O OFF position At this point the compressor is ready for use Operating on the switch of the pressure switch fig 2 the compressor starts pumping air in the reservoir through the delivery hose The absence of pressure in the head facilitates subsequent restart When air is used the compressor restarts automatically when the lower calibration value is reached approx 2 bar between upper and lower The pressure inside the reservoir can be checked on the gauge provided fig 4 6