ENDA (Турция) EC2401UV ec2401 онлайн [2/2] 841054
![ENDA (Турция) EC2401UV ec2401 онлайн [2/2] 841054](/views2/2076253/page2/bg2.png)
1.Programming Mode
000.0
2.Changing the Parameter Values
3.Using the Keypads.
dn
up
While "Programming Mode", by pressing to key for 2 seconds, the parameter value displayed and can be changed by using navigation keys. If no
operation is performed for 3 seconds or by pressing to key, the current parameter name will be displayed. If keys are pressed during the parameter
name displayed, "Running Mode" will be entered.
Cmod
EC2401
ENDA
SET
SET
000.0
SET
SET
Provides access to the previous parameter in "Programming Mode and decreases the
selected parameter value". If pressed continuously, the parameter value decreases rapidly.
Provides access to the next parameter in "Programming Mode and increases the selected
parameter value". If pressed continuously, the parameter value increases rapidly.
SET
Provides to reset the counter value in "Running Mode".
Provides to set the selected parameter value in "Programming Mode".
Reset key in “Running Mode”.
Parameter set key in “Programming Mode”
Indicates measured value and set values in “Running Mode”.
Indicates the parameters and names in “Programming Mode”.
Increment key in “Running Mode” and “Programming Mode”.
Parameter selection key in “Programming Mode”.
By pressing continuously, parameter value increases rapidly.
By pressing keys together for 2 seconds, “Programming Mode” is enterd.
Decrement key in “Running Mode” and “Programming
Mode”.Parameter selection key in “Programming Mode”.
By pressing continuously, parameter value decreases rapidly.
Measurement
value
Measurement
value
Programming
Mode
If the Counter (Cmod) mode set to (up), the Counter value increments by counting up to the value of the parameter.
If the Counter (Cmod) mode set to (dn), the Counter value decrements by counting up to the value of the (dn) parameter.
If the counter value is less than the value of the (dn) parameter, the counter value will be synchronized to the value of the (dn) parameter.
(up)
2/2
EC2401-EN-04-220103
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah. Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18
ENDA
TM
DEVICE PARAMETERS
FrEQ
Min.
Max.
Unit
Default
Value
Input frequency selection.
0 = 50Hz, 1 = 100Hz, 2 = 500Hz, 3= 1KHz, 4 = 5KHz, 5 = 10KHz
0
5
0
Parameter
Name
Description
Cmod
dn
Counting direction parameter. up = Up, dn = Down
up
up
up
dn
Up direction counting.
Down direction counting.
0
0
9999
9999
1000
1000
Похожие устройства
- ENDA (Турция) ETS1410LV ets1410LV
- Dors CT 3020 SYS-040926 Руководство по эксплуатации DORS CT 3020
- НТК Приборэнерго WTM-01 0210550010736 Инструкция по эксплуатации
- TELE 711141 Техническое описание
- TELE TBG30.18 12-48VDC 711056 Инструкция к товару
- TELE TBG70.18 12-48VDC 711435 Техническое описание
- TELE TBG70.29 12-48VDC 711408 Техническое описание
- Krona FIONA E 600 white PB Инструкция по эксплуатации
- TELE TBW30.18 230VAC 50Hz 711050 Инструкция к товару
- TELE TBW70.18 230VAC 50Hz 711430 Техническое описание
- TELE TBW70.29 230VAC 50/60Hz 711350 Техническое описание
- TELE TBW70.89 115VAC 50/60Hz 711140 Техническое описание
- DELTAKIP Delta-Kip DK-HM-1 (Белый, 10/60VDC) DK-A0000006 Паспорт
- DELTAKIP Delta-Kip DK-HM-1 (Черный, 220V) DK-A0000005 Паспорт
- DELTAKIP Delta-Kip DK-HM-8L с кнопкой сброс, чёрный 110-240VAC DK-A0000007 Паспорт
- МЗЭП многотарифный Данные из ФСА
- МЗЭП многотарифный Сертификат об УТ СИ
- МЗЭП многотарифный Данные из ФСА
- МЗЭП многотарифный Сертификат об УТ СИ
- МЗЭП многотарифный Данные из ФСА