Condtrol XLiner Combo [20/23] Xliner xliner combo condtrol xliner xliner combo condtrol

Condtrol XLiner Combo [20/23] Xliner xliner combo condtrol xliner xliner combo condtrol
XLiner / XLiner Combo CONDTROL
XLiner / XLiner Combo CONDTROL
38
39
user manual user manual
EN EN
When the maximum deviation exceeds 0.8 mm, you should contact
CONDTROL service centre.
Attention!
Always use only the middle of the laser line for marks. The width of the laser
line changes with distance. The instrument automatically switches off in 60
minutes of continuous work. If it is necessary, switch on the instrument and
continue working.
Orthogonal directions construction ( XLiner Combo only)
Check the 90° including angle of cross dot and the front, left, right dots.
Installing the instrument on the tripod, and put them in the centre of 6m x 6m
room, then switch on all the laser beams and dots.
Face the cross dot and front, left, right dots to the walls, the down dot aims
the floor, mark A, B, C, D, E respectively.
Rotate the instrument 90° around the down dot, mark A1, B1, C1, D1 on the
walls, measure respectively the distances of A to C1, B to D1, C to B1 and
D to A1.
If the value is larger than 2 mm, the instrument must be returned to
CONDTROL service centre.
USING WITH ACCESSORIES*
*supplied in addition
Working with the detector
To work with the detector press the button 2 located on the keypad, the
instrument is switched to the pulsed mode. The indicator 4 lights up.
The laser radiation detector
increases a working range up
to 100 meters. The detector is
intended for working in the streets
or in light conditions. The detector
is supposed to be used at a distance
not less than 3 meters from the
instrument. The detector can be
fixed to the station rod by means of
the multifunction base.
ATTENTION! The detector defines
a modulated signal from XLiner
Combo and does not define permanent laser radiation or a point. Keep clean
the sensitive field of the receiver, wipe it with a soft cloth, and do not use
reactive liquids (spirit, solvents, etc).
To switch on the detector press button «ON/OFF».
By pressing the button «SOUND» you can switch on or switch off the sound
signal of the search of the radiation axis.
The corresponding symbol appears on the indicator field of the detector.
The search of the laser radiation axis is carried out by smooth moving of the
detector on a vertical. At the moment when the laser is found in the sensitive
field of the receiver, there is an arrow on the screen, directed upwards or
downwards, corresponding to a direction in which it is necessary to move
the detector to find a centre. The sound signal is heard. At the moment
when the laser emitter axis corresponds to the centre of the sensitive
button «SOUND»
button «ON/OFF»