Hikoki G3623DA G3623DARAZ [15/300] English

Hikoki G3623DA G3623DARAZ [15/300] English
15
English
The declared vibration total value has been measured in
accordance with a standard test method and may be used
for comparing one tool with another.
It may also be used in a preliminary assessment of exposure.
WARNING
The vibration emission during actual use of the power
tool can di er from the declared total value depending in
the ways in which the tool is used.
Identify safety measures to protect the operator that
are based on an estimation of exposure in the actual
conditions of use (taking account of all parts of the
operating cycle such as the times when the tool is
switched o and when it is running idle in addition to the
trigger time).
NOTE
Due to HiKOKI’s continuing program of research and
development, the speci cations herein are subject to
change without prior notice.
TROUBLESHOOTING
Use the inspections in the table below if the tool does not operate normally. If this does not remedy the problem, consult your
dealer or the HiKOKI Authorized Service Center.
1. Power tool
Symptom Possible cause Remedy
Tool doesn’t run No remaining battery power Charge the battery.
Battery isn’t fully installed. Push the battery in until you hear a click.
Foreign matter is keeping the lock pin
pressed down.
Remove the foreign matter from the lock pin.
The battery is installed while the switch is
turned ON.
Turn the switch OFF and then ON again.
Tool suddenly stopped Tool was overburdened Get rid of the problem causing the
overburden.
Overload protection is in operation.
The battery is overheated. Let the battery cool down.
Abnormal noise.
Grinding wheel shakes
Wheel nut is loose. Fully tighten the wheel nut.
The wheel nut, wheel rusher, grinding
wheel, etc. are improperly installed facing
the wrong direction.
Check the installed direction and correctly
install the parts.
Foreign matter is caught between the wheel
nut, wheel washer, grinding wheel, etc.
Remove the foreign matter.
Brake doesn’t operate
properly.
Main unit may be at fault. Immediately discontinue use and contact
your dealer for repairs.
Battery cannot be installed Attempting to install a battery other than that
speci ed for the tool.
Please install a multi volt type battery.
2. Charger
Symptom Possible cause Remedy
The charge indicator lamp
rapidly ickers purple, and
battery charging doesn’t
begin.
The battery is not inserted all the way. Insert the battery rmly.
There is foreign matter in the battery
terminal or where the battery is attached.
Remove the foreign matter.
The charge indicator lamp
blinks red, and battery
charging doesn’t begin.
The battery is not inserted all the way. Insert the battery rmly.
The battery is overheated. If left alone, the battery will automatically
begin charging if its temperature decreases,
but this may reduce battery life. It is
recommended that the battery be cooled in
a well-ventilated location away from direct
sunlight before charging it.
Battery usage time is short
even though the battery is
fully charged.
The battery’s life is depleted. Replace the battery with a new one.
000Book_G3623DA_EU.indb 15000Book_G3623DA_EU.indb 15 2018/12/26 14:31:002018/12/26 14:31:00