7. SANITIZATION OF REVERSE OSMOSIS FILTER
Sanizaon of the reverse osmosis lter is recommended aer it has been in use for an extended
period (~ 6 months), and when the lter is not going to be used for 3 or more weeks at a me. It is
also desirable to sanize the system when replacing cartridges.
Using chlorine disinfectant tablets is recommended for reverse osmosis lter sanizaon.
1.
Shut o feed valve 5 and tank valve 6.
2. Remove and discard the pre-lter cartridges and carbon post-lter.
3. Unscrew cap of membrane housing and remove membrane using needlenose pliers if necessary. Put the membrane into
a ght bag and store in refrigerator at +2...+5°C (36...41
o
F).
4. Screw back on 2
nd
and 3
rd
pre-lter sumps, screw on membrane
housing cap, and connect the tube from the faucet directly to the
union tee without carbon post-lter.