6. Disconnect the tube going to the storage tank from the union tee
before the carbon post-lter, and into 3
rd
pre-lter’s outlet.
7. Put a disinfecon tablet in the 1
st
sump. Fill the sump with water and screw on.
8.
Aer 15 minutes, open tank valve 6.
9.
Open the feed valve 5 for 5 minutes.
10.
Close the tank valve 6 and leave the tank lled with chlorine soluon for 1-2 hours.
11.
Open tank valve 6 and drain all water from the tank to the sink. Disconnect it from the third pre-lter and restore the
original tubing of the system.
12.
Put cartridges in sumps and install the sumps on their heads. Then, open tank valve 6 and feed valve 6.
13. Drain the tank and re-ll for at least three mes (unl chlorine odor cannot be smelt).
7.
SANITIZATION OF REVERSE OSMOSIS FILTER