This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2016
REVERSE OSMOSIS SYSTEM INSTALLER AND USER GUIDE
7. SANITIZATION OF REVERSE OSMOSIS FILTER
4.
5. Put a chlorine tablet in the 1
st
sump.
Fill the sump with water and screw on.
6.
Aer 15 minutes, open the drinking water faucet 3 and feed valve 5.
7.
When water running from the faucet 3 starts to smell like chlorine, close both the faucet 3 and feed valve 5.
8. Leave the system for 2-3 hours.
9.
Open faucet 3 and feed valve 5 and let water run unl bleach odor is gone.
10.
Install all consumable parts back into the system. Open tank valve 6 and feed valve 5.
11. Drain the tank and re-ll for at least two mes (unl chlorine odor cannot be smelt).
Put a chlorine tablet