Buffalo LS-WSX1.0TLR1EU [82/92] Note the error may also be viewed from nas navigator2

Buffalo LS-WSX1.0TLR1EU [82/92] Note the error may also be viewed from nas navigator2
Appendix
LinkStation Setup Manual
8181
The Info/Error LED blinks red to indicate an error.
The error may be identied by the pattern of blinking.
Note: – The error may also be viewed from NAS Navigator2.
Error code Error details
E00 MPU is abnormal; no power.
E01 DRAM data line is abnormal.
E02 DRAM address line is abnormal.
E03 RTC chip is abnormal.
E04 Kernel failure.
E14 The RAID array cannot be mounted. Turn o power, then turn power on again.
If the same error is displayed, re-congure RAID.
E15 I/O error of hard drive.
E16 The hard drive is not connected, or data transfer has failed.
E17 Controller error.
E21 Controller error.
E23 The hard drive has crashed.
Place Status
10’s place The LED illuminates for 1 second every 0.3 seconds.
The number of ashes is the tens place of the error code.
1’s place The LED illuminates for 0.5 seconds every 0.3 seconds.
The number of ashes is the ones place of the error code.
Power LED
Status Meaning
Solid Blue The LinkStation is powered on.
Blinking blue The LinkStation is starting up or shutting down.
O The LinkStation is o.

Содержание

Скачать