Clatronic LB 3599 [33/62] Storage

Clatronic LB 3599 [33/62] Storage
33
Tank
1. Remove the tank from the base appliance.
2. Rinse the tank with clear water.
3. In case of limescale, add about 100 ml of household
vinegar to the cleaning water. Allow the solution to work for
approx. 10 minutes.
4. Remove any lime deposit at the steam nozzle and tank cap
by using some household vinegar.
5. Rinse the tank out once more with clear water.
6. Allow the tank to dry before you close it again.
Ceramic lter
After approx 1000 litres of water ow, the ceramic balls lose
their effect. We recommend that you change the ceramic lter.
Please contact your dealer to ask about a new ceramic lter.
Replacing the lter
The lter is located on the back of the tank cap.
The lter can be unlocked. Use the same way to lock the new
lter in place.
Cleaning around the unit
If the unit has been used over a long period, limescale deposits
may occur around the unit, in spite of the integrated ceramic
lter. Clean the surface on which the unit rests and all objects
found close to the unit, on a regular basis.
Storage
Clean the appliance as described and allow it to dry.
Pack the lter with the ceramic spheres separately into a
bag when it is dry. Store it in a cool, shady place.
We recommend that you keep the appliance in the original
packaging if it will not be used for long periods.
Always store the appliance out of the reach of children in a
dry, well ventilated place.
Troubleshooting
Problem Cause Solution
The appliance is not
functioning.
No power supply Check the power supply.
Fault in the electronics Contact the dealer or the service centre.
The device is turned on, but
no mist is being generated.
The tank is empty. Fill the tank.
The oat gauge in the bottom
right of the water vessel is
jammed.
Check the oat gauge in the water vessel. It must slightly move up
and down.
Too much water in the vessel. Remove some water and then tighten the tank cap again.
Too little mist is coming out of
the nozzle.
The ultrasound probe is soiled. Clean the ultrasound probe as described above.
The water is dirty. Replace the water.
Setting too low. Press the MIST button to change the setting.
Water too cold. Add some warm water.
No water running from the
tank into the water vessel.
The lter or the tank cap valve
is blocked.
Flush both parts or replace the lter.
Steam escapes next to the
nozzle.
Steam nozzle not correctly
positioned.
Install the steam nozzle properly.
A bad smell is developing. The appliance is new. Remove the tank, take off the lid. Allow the appliance to air in a cool
place for 12 hours.
The water is too old or soiled. Replace the water and clean the appliance.
The appliance is abnormally
loud.
The appliance is unstable. Check the stand space.
The tank is almost empty. Rell the tank.
The display shows HF or LF. Poor contact of the air humidity
sensor.
Turn off the device for 2 hours. Disconnect the plug. Then try again.
If the error remains, contact our customer service.
The air humidity sensor has
become wet.
Move the air humidier to a location with better air circulation.