116 5 ELECTRICAL PARTS If the electrolyte level falls during charging refill with distilled water to the upper level mark Near the ertd of the charging period adjust the specific gravity to between 1 270 and 1 290 between 1 250 and 1 270 in tropical areas and continue charging for two to three additional hours Explosive hydrogen gas is discharged from the cells therefore do not charge batteries near any open fire Always turn charger off before connecting or disconnecting batteries After charging add distilled or battery water to the cells to bring the electrolyte to the upper level mark Tighten cell caps firmly and wash off with clean water any acid spilled The battery is now ready for installation When installing motorcycle battery be sure not to pinch the battery vent tube Explosion may result if the exhaust tube is blocked c Preventative Maintenance The battery is being recharged all the while the engine is running Further while running the load such as the use of the winker horn are placed on the battery discharged as the result the battery is being discharged at the some time it is being recharged In the long run the discharge and the recharge is in balance The system has been designed in this manner Under certain condition when the balance is upset then trouble develops To obtain maximum life from the battery it is necessary to locate this trouble and take the appropriate action early The trouble to the battery are mainly external such as cracked case broken terminal disconnected lead wire The battery condition trouble corrective action are shown in the following section 5 10 trouble shooting and corrective action P143