Suzuki GSF 400 (1991-1993) [144/270] Side stand up on

Содержание

ELECTRICAL SYSTEM 6 The circuit consists of relay iamp diode and switches and decides to live the ignition coil depending on the position of the TRANSMISSION and SIDE STAND with the neutral and side stand switches work ing mutually The ignition coil lives only in two situations as follows 1 Transmission NEUTRAL ON Side stand DOWN OFF The current flow A turns ON the relay and the ignition coil lives even the side stand is kept down This is for warming up the engine IGNITION SW ON SIDE STAND RELAY ON BATTERY IGNITION COIL NEUTRAL LAMP DIODE NEUTRAL SW ON SIDE STAND SW SIDE STAND DOWN POSITION 2 Side stand UP ON The current flow turns ON the relay and the ignition coil lives The engine can be easily start ed at any transmission position IGNITION SW ON SIDE STAND RELAY ON BATTERY IGNITION COIL NEUTRAL SW OFF SIDE STAND SW UP POSITION