Suunto Cobra2 [25/56] Mandatory safety stops
![Suunto Cobra2 [25/56] Mandatory safety stops](/views2/1013667/page25/bg19.png)
5.10.2. Mandatory Safety Stops
When the ascent rate exceeds 10 m/33 ft per minute continuously for more than 5 seconds,
the microbubble build-up is predicted to be more than is allowed for in the decompression
model. The Suunto RGBM calculation model responds to this by adding a Mandatory
Safety Stop to the dive. The time of this Mandatory Safety Stop depends on the severity
of the ascent rate excess.
The STOP sign appears in the display and when you reach the depth zone between 6 m
and 3 m/20 ft and 10 ft, the CEILING label, ceiling depth, and the calculated Safety Stop
time also appear in the display. You should wait until the Mandatory Safety Stop warning
disappears. The total length of the Mandatory Safety Stop time depends on the seriousness
of the ascent rate violation.
WHEN CEILING AND STOP ARE
DISPLAYED, MAKE A ONE MINUTE
MANDATORY SAFETY STOP IN THE
DEPTH ZONE BETWEEN 6 M AND 3 M.
You must not ascend shallower than 3 m/10 ft with the Mandatory Safety Stop warning
on. If you ascend above the Mandatory Safety Stop ceiling, a downward pointing arrow
will appear and a continuous beeping starts. You should immediately descend to, or below,
the Mandatory Safety Stop ceiling depth. If you correct this situation at any time during
the dive, there are no effects on the decompression calculations for future dives.
WHEN CEILING AND STOP
ARE DISPLAYED, IMMEDIATELY
(WITHIN 3 MINUTES) DESCEND
TO OR BELOW CEILING.
If you continue to violate the Mandatory Safety Stop, the tissue calculation model is affected
and the dive computer shortens the available no-decompression time for your next dive.
In this situation, it is recommended that you prolong your surface interval time before your
next dive.
5.11. Deep stops
Deep Stops are safety stops that occur deeper than traditional stops, with the purpose of
minimizing microbubble formation and excitation.
The Suunto RGBM model calculates deep stops iteratively, placing the first stop about
halfway between the maximum depth and the ceiling depth. After the first Deep Stop is
completed, another Deep Stop will be prompted halfway to the ceiling, and so on until the
ceiling depth is reached.
The Deep Stop length can be set to 1 or 2 minutes.
NOTE
With Deep Stops on, the Recommended Safety Stops will still be
activated at the end of the dive.
25
Содержание
- Table of contents 3
- Welcome to the world of suunto diving instruments 5
- Warnings cautions and notes 6
- Button symbols and functions 9
- Navigating in the menus 9
- Suunto cobra2 at a glance 9
- Getting started with your suunto cobra2 11
- Setting the alarm 11
- Setting the date 11
- Setting the time 11
- Time mode settings 11
- Ac water contacts 12
- Setting the backlight 12
- Setting the tones 12
- Setting the units 12
- Compass display 13
- Learning how to use your compass 13
- Tilt sensor 13
- Compass settings 14
- Declination 14
- Locking a bearing 14
- Calibration 15
- Before diving 16
- Dive computer limitations 16
- Emergency ascents 16
- The suunto rgbm deep stop algorithm 16
- Audible and visual alarms 17
- Nitrox 17
- Air integration 18
- Error conditions 18
- Connecting suunto cobra2 to a regulator 19
- Dive mode settings 19
- Setting the depth alarm 19
- Setting the dive time alarm 19
- Setting the nitrox values 20
- Setting the personal altitude adjustments 20
- Accessing dive mode 21
- Activation and pre checks 21
- Setting the rgbm values 21
- Setting the safety stops deep stops 21
- Setting the sample rate 21
- Battery power indication 22
- Dive mode activation 22
- Diving at altitude 23
- Personal adjustments 23
- Recommended safety stops 24
- Safety stops 24
- Deep stops 25
- Mandatory safety stops 25
- Basic dive data 26
- Diving 26
- Diving in air mode diveair 26
- Bookmark 27
- Tank pressure data 27
- Ascent rate indicator 28
- Decompression dives 28
- Safety stops 28
- Ceiling ceiling zone floor and decompression range 29
- Display below the floor 29
- Display above the ceiling 30
- Display above the floor 30
- Display at the ceiling zone 30
- Before diving in nitrox mode 31
- Default nitrox settings 31
- Diving in nitrox mode divenitrox 31
- Oxygen displays 31
- Diving in gauge mode divegauge 32
- Gas change and multiple breathing gas mixes 32
- Oxygen limit fraction olf 32
- After diving 34
- Dive numbering 34
- Repetitive dive planning 34
- Surface interval 34
- Dive planning mode plannodec 35
- Flying after diving 35
- Plan mode 35
- Dive numbering shown during dive planning 36
- Dive simulator 36
- Simulation mode plansimulator 36
- Dive logbook memlogbook 37
- Memory mode 37
- Dive history memhistory 38
- Suunto dive manager sdm 38
- Www suuntosports com and suunto diving world at www suunto com diving 39
- Care and maintenance 40
- Care of your dive computer 40
- Maintenance 40
- Water contacts and buttons 40
- Battery kit 41
- Battery replacement 41
- Battery replacement procedure 41
- Required tools 41
- Water resistance inspection 41
- Technical data 44
- Technical specifications 44
- Suunto rgbm adaptive decompression 45
- No decompression limits 46
- Altitude diving 47
- Oxygen exposure 47
- Copyright 48
- Intellectual property 48
- Patent notice 48
- Trademark 48
- After sales service 49
- Disclaimers 49
- Limits of liability and iso 9001 compliance 49
- User s responsibility 49
- Warranty 50
- Disposal of the device 51
- Glossary 52
- Two year warranty 55
Похожие устройства
- Yamaha PSR-E213 Инструкция по эксплуатации
- Texas Lilli 572 B Инструкция по эксплуатации
- Mystery MGM-1450 Инструкция по эксплуатации
- Siemens SK76M530EU Инструкция по эксплуатации
- JVC TH-A10R Инструкция по эксплуатации
- Suunto Cobra Инструкция по эксплуатации
- Yamaha PSR-E223 Инструкция по эксплуатации
- Champion ВC7712 Инструкция по эксплуатации
- Loewe Assist Multi-Control Инструкция по эксплуатации
- Bosch MFW 1501 Инструкция по эксплуатации
- Panasonic WV-SF330 Инструкция по эксплуатации
- Hyundai H-HT5114-N Инструкция по эксплуатации
- Yamaha PSR-E303 Инструкция по эксплуатации
- Supra MGS 1350 Инструкция по эксплуатации
- Elitech КБ 60 Инструкция по эксплуатации
- Loewe Auro 2216 Инструкция по эксплуатации
- Yamaha PSR-E313 Инструкция по эксплуатации
- Panasonic WV-SP300 Инструкция по эксплуатации
- Hyundai H-HT5113-N Инструкция по эксплуатации
- Champion ВC 6611 Инструкция по эксплуатации