Suunto Cobra2 [26/56] Basic dive data
![Suunto Cobra2 [26/56] Basic dive data](/views2/1013667/page26/bg1a.png)
6. DIVING
This section contains instructions on how to operate the dive computer and interpret its
displays. You’ll find that this dive computer is easy to use and read. Each display shows
only the data relevant to that specific diving mode.
6.1. Diving in AIR mode (DIVEair)
In this section, we look at how to make the most of the dive computer when diving with
standard air. To activate DIVEair mode, please see Section 5.9.1. Accessing DIVE mode.
DIVE HAS JUST BEGUN AND
AVAILABLE NO-DECOMPRESSION
TIME IS OVER 99 MINUTES SO NO
VALUE IS DISPLAYED.
NOTE
The dive computer will remain in the Surface mode at depths less
than 1.2 m/4 ft. At depths greater than 1.2 m/4 ft the instrument will
go into the DIVE mode automatically. However, it is recommended
that you activate the DIVE Mode manually in order to perform the
necessary dive pre-checks.
6.1.1. Basic dive data
During a No-decompression dive, the following information is displayed:
•
your present depth in meters/feet
•
the available no-decompression time in minutes as NO DEC TIME
•
the ascent rate presented as a bar graph on the right side
•
the Diver Attention Symbol if surface interval should be prolonged (see Table 7.1,
Alarms)
DIVE DISPLAY - PRESENT DEPTH IS 15 M,
NO-DECOMPRESSION STOP TIME LIMIT IS 38 MIN.
ELAPSED DIVE TIME IS 13 MIN. 99 MINUTES OF
REMAINING AIR TIME AND 202 BAR TANK PRESSURE.
Alternative displays, by pressing the UP/DOWN buttons, show:
•
the elapsed dive time in minutes, shown as DIVE TIME
•
the water temperature in °C/°F
•
the maximum depth during this dive in meters/feet, indicated as MAX
•
the current time, shown as TIME
DOWN BUTTON TOGGLES
BETWEEN MAXIMUM DEPTH
AND CURRENT TIME.
26
Содержание
- Table of contents 3
- Welcome to the world of suunto diving instruments 5
- Warnings cautions and notes 6
- Button symbols and functions 9
- Navigating in the menus 9
- Suunto cobra2 at a glance 9
- Getting started with your suunto cobra2 11
- Setting the alarm 11
- Setting the date 11
- Setting the time 11
- Time mode settings 11
- Ac water contacts 12
- Setting the backlight 12
- Setting the tones 12
- Setting the units 12
- Compass display 13
- Learning how to use your compass 13
- Tilt sensor 13
- Compass settings 14
- Declination 14
- Locking a bearing 14
- Calibration 15
- Before diving 16
- Dive computer limitations 16
- Emergency ascents 16
- The suunto rgbm deep stop algorithm 16
- Audible and visual alarms 17
- Nitrox 17
- Air integration 18
- Error conditions 18
- Connecting suunto cobra2 to a regulator 19
- Dive mode settings 19
- Setting the depth alarm 19
- Setting the dive time alarm 19
- Setting the nitrox values 20
- Setting the personal altitude adjustments 20
- Accessing dive mode 21
- Activation and pre checks 21
- Setting the rgbm values 21
- Setting the safety stops deep stops 21
- Setting the sample rate 21
- Battery power indication 22
- Dive mode activation 22
- Diving at altitude 23
- Personal adjustments 23
- Recommended safety stops 24
- Safety stops 24
- Deep stops 25
- Mandatory safety stops 25
- Basic dive data 26
- Diving 26
- Diving in air mode diveair 26
- Bookmark 27
- Tank pressure data 27
- Ascent rate indicator 28
- Decompression dives 28
- Safety stops 28
- Ceiling ceiling zone floor and decompression range 29
- Display below the floor 29
- Display above the ceiling 30
- Display above the floor 30
- Display at the ceiling zone 30
- Before diving in nitrox mode 31
- Default nitrox settings 31
- Diving in nitrox mode divenitrox 31
- Oxygen displays 31
- Diving in gauge mode divegauge 32
- Gas change and multiple breathing gas mixes 32
- Oxygen limit fraction olf 32
- After diving 34
- Dive numbering 34
- Repetitive dive planning 34
- Surface interval 34
- Dive planning mode plannodec 35
- Flying after diving 35
- Plan mode 35
- Dive numbering shown during dive planning 36
- Dive simulator 36
- Simulation mode plansimulator 36
- Dive logbook memlogbook 37
- Memory mode 37
- Dive history memhistory 38
- Suunto dive manager sdm 38
- Www suuntosports com and suunto diving world at www suunto com diving 39
- Care and maintenance 40
- Care of your dive computer 40
- Maintenance 40
- Water contacts and buttons 40
- Battery kit 41
- Battery replacement 41
- Battery replacement procedure 41
- Required tools 41
- Water resistance inspection 41
- Technical data 44
- Technical specifications 44
- Suunto rgbm adaptive decompression 45
- No decompression limits 46
- Altitude diving 47
- Oxygen exposure 47
- Copyright 48
- Intellectual property 48
- Patent notice 48
- Trademark 48
- After sales service 49
- Disclaimers 49
- Limits of liability and iso 9001 compliance 49
- User s responsibility 49
- Warranty 50
- Disposal of the device 51
- Glossary 52
- Two year warranty 55
Похожие устройства
- Yamaha PSR-E213 Инструкция по эксплуатации
- Texas Lilli 572 B Инструкция по эксплуатации
- Mystery MGM-1450 Инструкция по эксплуатации
- Siemens SK76M530EU Инструкция по эксплуатации
- JVC TH-A10R Инструкция по эксплуатации
- Suunto Cobra Инструкция по эксплуатации
- Yamaha PSR-E223 Инструкция по эксплуатации
- Champion ВC7712 Инструкция по эксплуатации
- Loewe Assist Multi-Control Инструкция по эксплуатации
- Bosch MFW 1501 Инструкция по эксплуатации
- Panasonic WV-SF330 Инструкция по эксплуатации
- Hyundai H-HT5114-N Инструкция по эксплуатации
- Yamaha PSR-E303 Инструкция по эксплуатации
- Supra MGS 1350 Инструкция по эксплуатации
- Elitech КБ 60 Инструкция по эксплуатации
- Loewe Auro 2216 Инструкция по эксплуатации
- Yamaha PSR-E313 Инструкция по эксплуатации
- Panasonic WV-SP300 Инструкция по эксплуатации
- Hyundai H-HT5113-N Инструкция по эксплуатации
- Champion ВC 6611 Инструкция по эксплуатации