Suunto Cobra — информация о дайвинге: профили, память и управление [46/78]
Превью страниц
Страница 46 /
78
![Suunto Cobra [46/78] Dive profile memory prof](/views2/1013676/page46/bg2e.png)
44
Page III (Fig. 4.9.)
• dive number in the dive series
• average depth
• surface interval time before the dive
• ∆P describing Cylinder pressure drop during the dive.
Page IV (Fig. 4.10.)
• dive number in the dive series
• the profi le of the dive, automatic scrolling during which:
• logbook symbol blinks when the user has pressed the PLAN button for
Bookmark
• blinking SLOW label when registered
• blinking ASC TIME label when the dive became a decompression dive.
Press the SMART (Select) button once to change the scroll buttons to scroll the
different dives forward and backward (Fig. 4.11.). Press the SMART (>Select)
button again to change function of the scroll buttons back to scroll the different
pages of the selected dive. When searching the dives, only the page 1 is shown. The
END text is displayed between the oldest and the most recent dive (Fig. 4.12.).
The memory will retain approximately the last 36 hours of dive time. After that,
when new dives are added, the oldest dives are deleted. The contents of the memory
will remain when the battery is changed (assuming that the replacement has been
done according to the instructions).
DIVE PROFILE MEMORY [PROF]
The scrolling of the profi le will start automatically when the Logbook page IV
(PROF) is entered.
With the default setting, the dive profi le is recorded and displayed in 20-second
increments with each display being shown for about three seconds. The depths
shown are the maximum values of each interval.
Pressing any button stops the scrolling of the profi le.
NOTE! Several repetitive dives are considered to belong to the same repetitive
dive series if the no-fl ying time has not ended. See “Dive Numbering” in section
3.6.2. for further information.
Содержание
- Asc time p.2
- S l o w p.2
- Quick reference guide p.2
- Options p.2
- Max avgpo2 p.2
- Ceiling p.2
- Bar psi p.2
- Fioh laajaniityntie 1 fin 01620 vantaa finland notifi ed body no 430 has ec type examined this type of personal protective equipment p.3
- En 250 respiratory equipment open circuit self contained compressed air diving apparatus requirements testing marking p.3
- Definition of warnings cautions and notes p.3
- Copyright trademark and patent notice p.3
- The tank pressure gauge and the parts of this product used in measuring the tank pressure meet the requirements set in the section of the european standard en 250 that concern tank pressure measurements the instruments must be serviced by an authorized dealer every second year or after 200 dives whichever comes fi rst p.3
- The ce mark is used to mark conformity with the european union emc directive 89 336 eec the suunto dive instruments fulfi ll all the required eu directives p.3
- Pren 13319 diving accessories depth gauges and combined depth and time measuring devices functional and safety requirements test methods is a european diving depth gauge standard draft the cobra is designed to comply with this draft standard p.3
- Pren 13319 p.3
- Iso 9001 p.3
- Warnings p.4
- Warning p.4
- Warning p.5
- Warning p.6
- Warning p.7
- Warnings p.8
- Table of contents p.8
- Introduction p.8
- Getting acquainted p.8
- Diving with the cobra p.8
- Care and maintenance p.9
- Warranty p.9
- Technical description p.9
- Menu based modes p.9
- Glossary p.9
- Introduction p.10
- Continuous decompression with suunto rgbm p.10
- Choice of operating modes and set up options p.10
- Safety precautions p.11
- Emergency ascents p.11
- Dive computer limitations p.11
- Nitrox p.12
- Getting acquainted p.13
- Functions p.13
- Connecting the cobra to a regulator p.13
- Push buttons p.14
- Water contacts p.15
- Diving with the cobra p.16
- Before diving p.16
- Activation and prechecks p.16
- Table 3 battery power indicator p.17
- Battery power indicator and low battery warning p.17
- Dive planning plan p.18
- User definable functions and alarms p.19
- Dive numbering shown during dive planning p.19
- Safety stops p.20
- Recommended safety stop p.20
- Mandatory safety stop p.20
- Diving in air mode p.22
- Basic dive data p.22
- Cylinder pressure data p.23
- Bookmark p.23
- Air consumption rate with a high consumption rate the limit will be close to 50 bar 725 psi and with a low rate close to 35 bar 500 psi p.24
- The dive computer will warn you with three audible double beeps and a blinking pressure display when the cylinder pressure reaches 50 bar 725 psi fig 3 2 the next three double beeps are heard when the cylinder pressure reaches 35 bar 500 psi and when the remaining air time reaches zero p.24
- Note filling your bc will affect the air time calculation due to the temporary increase in air consumption p.24
- Note a change of temperature will affect the cylinder pressure and consequently the air time calculation p.24
- Low air pressure warnings p.24
- Table 3 ascent rate indicator p.25
- Consumed bottom time cbt p.25
- Ascent rate indicator p.25
- Warning p.26
- Decompression dives p.26
- Warning p.27
- Ceiling ceiling zone floor and decompression range p.27
- Warning p.28
- Display below the floor p.28
- Display at the ceiling zone p.29
- Display above the floor p.29
- Display above the ceiling p.29
- Diving in nitrox mode p.30
- Default nitrox settings p.30
- Before diving p.30
- Oxygen displays p.31
- Oxygen limit fraction olf p.32
- Diving in gauge mode p.33
- Surface interval p.34
- At the surface p.34
- Dive numbering p.35
- Flying after diving p.36
- Audible and visual alarms p.37
- Oxygen alarms in nitrox mode p.38
- Warning p.39
- Table 3 altitude adjustment ranges p.39
- High altitude dives and personal adjustment p.39
- Altitude adjustment p.39
- Table 3 personal adjustment ranges p.40
- Personal adjustment p.40
- Omitted decompression p.41
- Error conditions p.41
- The use of the menu based functions p.42
- Menu based modes p.42
- The list of the menu based modes p.43
- Simulation mode 2 simul p.43
- Set modes 3 set p.43
- Note the menu based modes cannot be activated until 5 minutes after the dive p.43
- Memories and data transfer 1 memory p.43
- Exit quit p.43
- By pressing the smart button for more than 1 second any menu based function or submode can be quit and the dive computer will return directly to the dive mode p.43
- Memories and data transfer 1 memory p.44
- Logbook and dive profile memory 1 logbook p.44
- Dive profile memory prof p.46
- Dive history memory 2 history p.47
- Data transfer and pc interface 3 tr pc p.47
- Simulation mode 2 simul p.49
- Dive simulator 1 simdive p.49
- Dive planning simulator 2 simplan p.50
- Set modes 3 set p.51
- Dive parameter settings 1 set dive p.51
- Altitude adjustment and personal adjustment settings 1 adj mode p.51
- Nitrox oxygen settings 4 nitrox p.52
- Maximum depth alarm setting 3 max dpth p.52
- Dive time alarm setting 2 d alarm p.52
- Setting time 2 set time p.53
- Adjusting time 1 adj time p.53
- Adjusting date 2 adj date p.53
- Adjusting daily alarm 3 t alarm p.53
- Backlight setting 1 light p.54
- Setting preferences 3 set pref p.54
- Dive computer units setting 2 units p.54
- Dive computer model setting 3 model air nitrox gauge p.54
- Water contacts and push buttons p.55
- Important information p.55
- Depth sensor p.55
- Care and maintenance p.55
- Care of your dive computer p.56
- Water resistance inspection p.57
- Maintenance p.57
- Caution p.57
- Battery replacement p.57
- Tools required p.58
- Caution p.58
- Battery replacement p.58
- Battery kit p.58
- The dive computer should now activate it s timekeeping mode and show time 18 00 6 00 pm and date sa 01 01 activate the instrument check that p.60
- Check after the fi rst dives for possible moisture under the transparent battery compartment lid indicating a leak p.60
- Caution p.60
- All display segments work the low battery warning is off the buzzer beeps and backlight works all the settings are correct reset current time date and other settings if necessary 17 reassemble computer into the console the instrument is now ready for use p.60
- Display shield replacement p.61
- Compass attachment p.61
- The no decompression limits displayed by the dive computer for the fi rst dive to a single depth see table 6 and table 6 are slightly more conservative than those permitted by the u s navy tables p.62
- Technical description p.62
- Table 6 no decompression time limits min for various depths m for the first dive of a series p.62
- Table 6 no decompression time limits min for various depths ft for the first dive of a series p.62
- Operating principles p.62
- No decompression limits p.62
- Surface intervals p.63
- Altitude diving p.63
- Suunto rgbm adaptive decompression p.64
- Reduced gradient bubble model suunto rgbm p.64
- Oxygen exposure p.65
- Diver attention symbol advice to extend surface interval p.65
- Technical specification p.66
- Warranty p.69
- Glossary p.70
- Disposal of the device p.74
- Modes and operations p.75
- Www suunto com p.78
Похожие устройства
-
Suunto Cobra2Инструкция по эксплуатации -
Suunto Cobra3Инструкция по эксплуатации -
Suunto ComboИнструкция по эксплуатации -
Suunto D4iИнструкция по эксплуатации -
Suunto D6Инструкция по эксплуатации -
Suunto D6iИнструкция по эксплуатации -
Suunto D9Инструкция по эксплуатации -
Suunto D9txИнструкция по эксплуатации -
Suunto GekkoИнструкция по эксплуатации -
Suunto HelO2Инструкция по эксплуатации -
Suunto StingerИнструкция по эксплуатации -
Suunto VyperИнструкция по эксплуатации
Узнайте о профилях дайвинга, управлении записями и памяти устройства. Получите информацию о глубине, времени и автоматическом скроллинге данных.