Suunto Cobra Инструкция по эксплуатации онлайн [67/78] 12851

65
Displays only in Nitrox mode:
Oxygen%: 21 - 50.
Oxygen partial pressure display: 1.2 - 1.6 bar depending on the limit
setting.
Oxygen Limit Fraction: 1 - 110% with 10% resolution (bar graph).
Logbook/Dive Profi le Memory:
Recording interval: 20 seconds (the recording interval can be set to 10s,
30s or 60s with the optional PC-interface unit and software), records the
maximum depth of each interval.
Memory capacity: approximately 36 hours of diving with 20 seconds
recording interval.
Depth accuracy: 0.3 m [1 ft].
Operating Conditions
Normal altitude range: 0 to 3000 m [10000 ft] above sea level.
Operating temperature: 0°C to 40°C [32°F to 104°F].
Storage temperature: -20°C to +50°C [-4°F to +122°F].
It is recommended that the instrument be stored in a dry place at room
temperature.
NOTE! Do not leave the dive computer in direct sunlight!
Tissue Calculation Model
Suunto RGBM algorithm (developed by SUUNTO and Bruce R.
Wienke, BS, MS and PhD).
9 tissue compartments.
Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480
minutes (on gassing). The off gassing halftimes are slowed down.
Reduced gradient (variable) “M” values based on diving habit and dive
violations. The “M” values are tracked up to 100 hours after a dive.
The EAN and oxygen exposure calculations are based on
recommendations by R.W. Hamilton, PhD and currently accepted
exposure time limit tables and principles.

Содержание

Скачать