Antari HZ-100 [5/28] Remote control operation

Antari HZ-100 [5/28] Remote control operation
4
dealer to replace a new muffler only (please note that the old muffler is unable to use
repeatedly after washing or brushing). Long term use of the unit which has the build-up
residue on the muffler may cause an unsteady operation of the compressor. It may even
cause danger of burn under serious conditions.
4. If you have followed the above operation steps, and you still experience low output,
mechanical noise or no output at all, unplug the unit immediately from the mains. Check
the fluid level, the external fuse, the remote control connection, and the power cable from
the wall. If all of the above appears to be O.K., plug the unit in again. If the hazer still
does not function, discontinue operation or it may result in permanent damage to the unit.
Return the machine to your Antari dealer. Always drain tank before mailing or
transporting this unit.
Remote Control Operation
HC-1:10 meter wired multi-function remote controller with ¼” stereo plug.
Red: CONTROL ON/OFF
Green: HAZE
Yellow: TIMER ON/OFF
DURATION and INTERVAL knobs
Connect the unit to the mains; set the power switch on the at rear of the machine to on.
Press the red button (CONTROL ON/OFF), the red indicator light will be on at the
same time. This haze machine is ready to operate.
Keep the green button (HAZE) pressed; the unit will produce continuous haze output.
Release the button to stop output. During this time, the red button (CONTROL
ON/OFF) is kept pressed while the red indicator light is still on.