Kramer RC-53DLC [11/20] Figure 4 defines the rc 53dlc rear panel for the european version

Kramer RC-53DLC [11/20] Figure 4 defines the rc 53dlc rear panel for the european version
8
RC-53DLC - Overview
Figure 4 defines the RC-53DLC rear panel for the European version.
Figure 4: RC-53DLC European Version Rear Panel
#
Feature
Function
1
Program USB Connector
Connect to a computer for firmware upgrade
When the unit is connected via K-NET to a Master
Room Controller, you can upgrade the firmware via
the USB or ETH ports of the Master Room Controller
2
Grounding Screw
Connect to grounding wire (see Section 3.2)
3
RS-232 Terminal Block
For factory use only
4
K-NET Terminal Block
Connect the GND to the Ground connection,
connect B (-) and A (+) to RS-485, and connect
+12V to +12V on the companion unit
The ground connection is sometimes connected to the
shield of the RS-485 cable (in most applications, it is
not connected)
5
K-NET Terminal Block
6
PROG Switch
For technical support use only (should be set to the
right in the direction of the arrow for normal
operation)
7
K-NET TERM Switch
Slide downwards (in the direction of the arrow) for
K-NET termination, slide upwards to leave bus
unterminated. The last physical device on a K-NET
bus must be terminated
You can reach the KNET termination switch by
inserting a small screwdriver into the gap between the
rear panel PCB and the metal rear panel cover.
Скачать