Kramer TP-104HD [13/33] The tp 121 internal polarity switches

Kramer TP-104HD [13/33] The tp 121 internal polarity switches
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Your TP-121/TP-122
10
6.1.1 The TP-121 Internal Polarity Switches
Figure 6 and Table 5 define the internal sync polarity switches inside the
TP-121.
Note, that you need to open the TP-121 unit to gain access to the Vs and Hs
Polarity switches. After setting the switches, close the TP-121 unit.
Figure 6: TP-121 Internal Polarity Switches
Table 5: Features of the TP-121 Internal Polarity Switches
Feature
Function
VS Switch Slide the switch down
2
, to set the V SYNC to negative polarity (NEG.);
slide the switch up, to set the V SYNC to its input polarity (NORM.)
HS Switch Slide the switch down
1
6.2 Your TP-122 XGA/Audio Line Receiver
, to set the H SYNC to negative polarity (NEG.);
slide the switch up, to set the H SYNC to its input polarity (NORM.)
This section describes the topside (see section 6.2.1), and the underside
2
6.2.2
(see section ) of the TP-122 XGA/Audio Line Receiver.
6.2.1 Your TP-122 XGA/Audio Line Receiver (Topside)
The TP-122 is an XGA/audio line receiver that receives the coded CAT 5
signal transmitted by a TP-121, decodes it and converts it to XGA, stereo
analog and S/PDIF digital audio outputs. The TP-122, with a TP-121,
allows an operation range of more than 300ft (more than 100m) over
standard CAT 5 cable.
1 By default, both switches are set down (for a negative V SYNC and H SYNC polarity)
2 The underside is identical on the TP-122 and TP-124
NORM.
NEG.

Содержание

Похожие устройства