Euroboor ELM [2/52] Operating and maintenance instructions for models 125 elm 50 elm 00 elm 000 and elm 000 elm

Euroboor ELM [2/52] Operating and maintenance instructions for models 125 elm 50 elm 00 elm 000 and elm 000 elm
PERMANENT
LIFTING MAGNETS
OPERATING AND MAINTENANCE INSTRUCTIONS FOR MODELS 125,
ELM.250, ELM.500, ELM.1000, AND ELM.2000
ELM.
FOREWORD NAMES OF THE MOST IMPORTANT PARTS OF THE
LIFTING MAGNET
TECHNICAL SPECIFICATIONS AND DIMENSIONS
You have purchased a EUROBOOR lifting magnet.
We thank you for the trust you have placed in our product.
These instructions contain all the information required for safe
and optimum use of the lifting magnet.
Read the instructions carefully and follow the directions.
Keep the instructions in a safe place close to the workplace.
On delivery check that the magnet is undamaged and
complete. If the equipment is damaged or incomplete contact
your supplier immediately.
The complete delivery consists of:
ź Magnet ELM.125, 250, 500, 1000, and
ELM.2000
ź Test certificate
ź Operating and maintenance instructions ELM.125,
ELM.250, ELM.500, ELM.1000, and ELM.2000 incl. EC
Declaration of Conformity
The ELM.125, ELM.250, ELM.500, ELM.1000, AND ELM.2000
are guaranteed for a term of 60 months.
The guarantee is not applicable to shortcomings that can be
wholly or partially attributed to:
ź failure to comply with the operating and maintenance
instructions or use considered as being other than normal.
ź normal wear.
ź modifications or repairs not performed by EUROBOOR or
an authorised agent.
In all correspondence regarding your lifting magnet always
state the information displayed on the type plate.
ELM. ELM. ELM.
Never use a damaged or incomplete magnet!
We herewith declare that the lifting magnets
ELM.250, ELM.500, ELM.1000, and ELM.2000 are in
conformity with the provisions of the Machinery Directive
(Directive 2006/42 EG as amended), with the harmonised
standards EN 12100-1, EN 12100-2 and with national
implementing legislation.
ELM.125,
Magnet
Instruction plate
+ type plate
Lifting eye
Handle
Handle lock
plate
Pole shoes
1
2
3
4
5
6
Type ELM.125, 250, 500, 1000, and
ELM.2000
ELM. ELM. ELM.
EN
For vertical manipulation capacity cca 20% of nominal ONLY!
DO THE TEST BEFORE VERTICAL MANIPULATION!
3
2
1
6
5
4
ELM.125 ELM.250 ELM.500 ELM.1000 ELM.2000
Lenght (mm) 93 152 246 306 478
Width (mm) 60 100 120 146 165
Height (mm) 120 180 180 236 273
(incl. Lifting eye)
Weight (kg) 2,6 10 19 38 85
Tested Lifting 400 800 1600 3200 6200
Capacity (daN)
Workload limit 125 250 500 1000 2000
for plates (kg)
Workload limit 50 125 250 500 1000
pipe and tube (kg)
Ø min / max (mm) 50/100 60/200 65/270 100/300 150/350
Albert Koster,