DAB DP 102 M [27/112] It is advisable that installation be carried out by skilled personnel in possession of the technical qualifications required by the specific legislation in force

DAB EUROCOM 30/80 T [27/112] It is advisable that installation be carried out by skilled personnel in possession of the technical qualifications required by the specific legislation in force
ENGLISH
17
 Storage temperature:
-10°C to +40°C
 Relative humidity of the air:
MAX. 95%
 Noise level:  For pumps intended for outdoor use: noise emission according to Directive
2000/14/CE.
 For other pumps: noise emission according to Directive EC 89/392/CEE and
subsequent amendments.
 Motor construction in conformity with standards CEI 2-3 - CEI 61-69 (EN 60335-2-41).
 The leads of the supply cables must have a rated section no smaller than that illustrated in the
following table:
Rated current:
of the appliance
A
Rated section
mm²
0,2
Flat twin tinsel cord
a
> 0,2 and 3
0,5
a
> 3 and 6 0,75
> 6 and 10
1,0 (0,75)
b
> 10 and 16
1,5 (1,0)
b
> 16 and 25 2,5
> 25 and 32 4
> 32 and 40 6
> 40 and 63 10
a
These cables may be used only if their length does not
exceed 2 m between the point in which the cable or its
sheath enters the appliance and its entry in the plug.
b
The cables with the sections indicated in brackets may be
used for mobile appliances if their length does not exceed 2
m.
5. MANAGEMENT
5.1
Storage
All the pumps must be stored indoors, in a dry, vibration-free and dust-free environment, possibly with
constant air humidity.
They are supplied in their original packaging and must remain there until the time of installation. If this is
not possible, the intake and delivery aperture must be accurately closed.
5.2
Transport
Avoid subjecting the products to needless jolts or collisions.
To lift and transport the unit, use lifting equipment and the pallet supplied standard (if applicable).
5.3
Weights
The adhesive label on the package indicates the total weight of the electropump.
6. WARNINGS
6.1
Skilled technical personnel
It is advisable that installation be carried out by skilled personnel in possession of
the technical qualifications required by the specific legislation in force.
The term skilled personnel means persons whose training, experience and instruction, as well
as their knowledge of the respective standards and requirements for accident prevention and
working conditions, have been approved by the person in charge of plant safety, authorizing
them to perform all the necessary activities, during which they are able to recognize and avoid
all dangers. (Definition for technical personnel IEC 364).
The appliance is not intended to be used by persons (including children) with reduced physical,
sensory or mental capacities, or who lack experience or knowledge, unless, through the
mediation of a person responsible for their safety, they have had the benefit of supervision or of
instructions on the use of the appliance. Children should be supervised to ensure that they do
not play with the appliance. (EN 60335-1 : 02)

Содержание