12Gb/s MegaRAID SAS RAID Controllers User Guide
February 2015
Glossary
hot spare
An idle, powered on, standby drive that is ready for immediate use in case of drive failure. A hot spare does not contain any user
data. A hot spare can be dedicated to a single redundant array or it can be part of the global hot-spare pool for all arrays managed
by the controller.
When a drive fails, the controller firmware automatically replaces and rebuilds the data from the failed drive to the hot spare. Data
can be rebuilt only from virtual drives with redundancy (RAID levels 1, 5, 6, 10, 50, and 60; not RAID level 0), and the hot spare must
have sufficient capacity.
I
internal SAS device
A SAS device installed inside the computer cabinet. These devices are connected by using a shielded cable.
M
main memory
The part of computer memory that is directly accessible by the CPU (usually synonymous with RAM).
N
NVSRAM
Acronym for nonvolatile static random access memory. An EEPROM (electronically erasable read-only memory) chip that stores
configuration information. See EEPROM.
P
PCI
Acronym for peripheral component interconnect. A high-performance, local bus specification that allows the connection of devices
directly to computer memory. The PCI Local Bus allows transparent upgrades from 32-bit data path at 33 MHz to 64-bit data path at
33 MHz, and from 32-bit data path at 66 MHz to 64-bit data path at 66 MHz.
PCI Express
Acronym for peripheral component interconnect Express. A high-performance, local bus specification that permits the connection
of devices directly to computer memory. PCI Express is a two-way, serial connection that transfers data on two pairs of
point-to-point data lines. PCI Express goes beyond the PCI specification in that it is intended as a unifying I/O architecture
for various systems: desktops, workstations, mobile, server, communications, and embedded devices.
peripheral devices
A piece of hardware (such as a video monitor, drive, printer, or CD-ROM) used with a computer and under the control of the
computer. SCSI peripherals are controlled through a MegaRAID SAS RAID controller (host adapter).
PHY
The interface required to transmit and receive data packets transferred across the serial bus.
Each PHY can form one side of the physical link in a connection with a PHY on a different SATA device. The physical link contains
four wires that form two differential signal pairs. One differential pair transmits signals, while the other differential pair receives
signals. Both differential pairs operate simultaneously and allow concurrent data transmission in both the receive and the
transmit directions.