Ritmix rpi-6100 pure sine [15/16] Protection and state instruction

Ritmix rpi-6100 pure sine [15/16] Protection and state instruction
Protection and state instruction
Function
State description
Restart work method
LED light Alarm AC output
Input low
voltage
alarm
Green on
Red o
Yes
Yes
When the voltage of the
battery return to the related
range, alarm stop
automatically.
Input low
voltage shut
down
Green on
Red on
No No
When the voltage of the
battery return to the related
range, the inverter will restart
work, green light on, red light
o.
Input over
voltage shut
down
Green on
Red on
No No
When the voltage of the
battery return to related
range, the inverter will restart
work, green light on, red light
o.
Over load
shut down
Green on
Red on
No No
Reduce the load to related
range, the inverter will restart
work, green light on, red light
o.
Over
temperature
shut down
Green on
Red on
Yes No
When the inside temperature
return to related range,
inverter will restart to work,
green light on, red light o.
Output
short circuit
Green on
Red o
No No
When short circuit stopped,
inverter restart to work
automatically.