Supermicro Blade SuperMicro SBI-7126T-S6 [5/74] Table of contents
![Supermicro Blade SuperMicro SBI-7126T-S6 [5/74] Table of contents](/views2/1190270/page5/bg5.png)
v
Table of Contents
Chapter 1 Introduction.......................................................................1-1
1-1 Overview.............................................................................................1-1
1-2 Product Checklist of Typical Components.....................................1-1
1-3 Blade Module Features....................................................................1-2
Processors..............................................................................................1-2
Memory...................................................................................................1-2
Storage....................................................................................................1-3
Density....................................................................................................1-3
1-4 Contacting Supermicro.....................................................................1-4
Chapter 2 System Safety..................................................................2-1
2-1 Electrical Safety Precautions...........................................................2-1
2-2 General Safety Precautions.............................................................2-2
2-3 Electrostatic Discharge Precautions ..............................................2-2
2-4 Operating Precautions......................................................................2-2
Chapter 3 Setup and Installation.................................................3-1
3-1 Overview.............................................................................................3-1
3-2 Installing Blade Modules..................................................................3-1
Powering Up a Blade Unit.......................................................................3-1
Powering Down a Blade Unit ..................................................................3-1
Removing a Blade Unit from the Enclosure............................................3-1
Removing/Replacing the Blade Cover....................................................3-2
Installing a Blade Unit into the Enclosure ...............................................3-2
3-3 Processor Installation .......................................................................3-4
3-4 Onboard Battery Installation............................................................3-5
3-5 Memory Installation...........................................................................3-6
Populating Memory Slots........................................................................3-6
DIMM Installation ....................................................................................3-8
3-6 Hard Disk Drive Installation .............................................................3-9
3-7 Installing the Operating System....................................................3-11
Installing with an External USB CD-ROM Drive....................................3-11
Installing via PXE Boot..........................................................................3-11
Installing via Virtual Media (Drive Redirection) .....................................3-12
3-8 Management Software ...................................................................3-12
Содержание
- Sbi 7126t s6 blade module user s manual 2
- Warning handling of lead solder materials used in this product may expose you to lead a chemical known to the state of california to cause birth defects and other reproductive harm 2
- About this manual 3
- Manual organization 3
- Preface 3
- 1 electrical safety precaution 5
- 1 overvie 5
- 2 general safety precaution 5
- 2 installing blade module 5
- 2 product checklist of typical component 5
- 3 blade module feature 5
- 3 electrostatic discharge precaution 5
- 3 processor installatio 5
- 4 contacting supermicr 5
- 4 onboard battery installatio 5
- 4 operating precaution 5
- 5 memory installatio 5
- 6 hard disk drive installatio 5
- 7 installing the operating syste 5
- 8 management softwar 5
- Chapter 1 introductio 5
- Chapter 2 system safet 5
- Chapter 3 setup and installatio 5
- Table of contents 5
- 1 control pane 6
- 1 introductio 6
- 2 bios update 6
- 2 mainboar 6
- 3 blade unit component 6
- 3 running setu 6
- 4 main bios setu 6
- 5 advanced setu 6
- 6 securit 6
- 9 configuring and setting up rai 6
- 9 hardware health informatio 6
- Chapter 4 blade module feature 6
- Chapter 5 raid setup procedur 6
- Chapter 6 bio 6
- A 1 bios post message 7
- A 2 bios post code 7
- Appendix a bios post code 7
- List of figures 9
- List of tables 11
- 1 overview 13
- 2 product checklist of typical components 13
- Chapter 1 introduction 13
- 3 blade module features 14
- Memory 14
- Processors 14
- Sbi 7126t s6 blade module user s manual 14
- Table 1 1 sbi 7126t s6 blade specification features 14
- Chapter 1 introduction 15
- Density 15
- Figure 1 1 full rack of blade enclosures and blade servers 15
- Storage 15
- 4 contacting supermicro 16
- Asia pacific 16
- Europe 16
- Headquarters 16
- Sbi 7126t s6 blade module user s manual 16
- 1 electrical safety precautions 17
- Chapter 2 system safety 17
- 2 general safety precautions 18
- 3 electrostatic discharge precautions 18
- 4 operating precautions 18
- Sbi 7126t s6 blade module user s manual 18
- 1 overview 19
- 2 installing blade modules 19
- Chapter 3 setup and installation 19
- Powering down a blade unit 19
- Powering up a blade unit 19
- Removing a blade unit from the enclosure 19
- Installing a blade unit into the enclosure 20
- Removing replacing the blade cover 20
- Sbi 7126t s6 blade module user s manual 20
- Chapter 3 setup and installation 21
- Figure 3 1 inserting a blade into the enclosure 21
- Figure 3 2 locking the blade into position 21
- 3 processor installation 22
- Sbi 7126t s6 blade module user s manual 22
- 4 onboard battery installation 23
- Chapter 3 setup and installation 23
- Figure 3 3 installing a processor in a socket 23
- 5 memory installation 24
- Battery holder 24
- Figure 3 4 installing the onboard battery 24
- Lithium battery 24
- Populating memory slots 24
- Sbi 7126t s6 blade module user s manual 24
- Table 3 1 populating twelve memory slots for interleaved operation 24
- Chapter 3 setup and installation 25
- Figure 3 5 12 slot dimm numbering 25
- Note the dimm slot number specified in table 3 1 equals the dimm slot to be populated a indicates that the dimm slot should be left unpopulated 25
- Note though multiple dimm memory module types and speeds may be supported you need to use dimm memory modules of the same speed and type 25
- Dimm installation 26
- Figure 3 6 installing a dimm into a memory slot 26
- Sbi 7126t s6 blade module user s manual 26
- 6 hard disk drive installation 27
- Chapter 3 setup and installation 27
- Figure 3 7 installing a hard drive in a carrier 28
- Sbi 7126t s6 blade module user s manual 28
- 7 installing the operating system 29
- Chapter 3 setup and installation 29
- Installing via pxe boot 29
- Installing with an external usb cd rom drive 29
- 8 management software 30
- 9 configuring and setting up raid 30
- Installing via virtual media drive redirection 30
- Sbi 7126t s6 blade module user s manual 30
- Chapter 4 blade module features 31
- Feature description 31
- Figure 4 1 sbi 7126t s6 blade module front view 31
- See figure 4 1 for a front view of the blade unit and table 4 1 for its features 31
- Table 4 1 sbi 7126t s6 blade module features 31
- This chapter describes the sbi 7126t s6 blade module installation and maintenance should be performed by experienced technicians only 31
- 1 control panel 32
- Each blade has a similar control panel figure 4 2 with power on off button a kvm connector a kvm button and four leds on the top front of the unit the numbers mentioned in figure 4 2 are described in table 4 2 32
- Figure 4 2 blade control panel 32
- Item function state description 32
- Sbi 7126t s6 blade module user s manual 32
- Table 4 2 blade control panel 32
- Chapter 4 blade module features 33
- Kvm button 33
- Kvm connector 33
- Led indicators 33
- Power button 33
- Table 4 3 blade module led indicators 33
- 2 mainboard 34
- Figure 4 3 b8dt6 mainboard 34
- 6 sas2 sata hard drive bays 35
- Bios chip 35
- Chapter 4 blade module features 35
- Dimm slots see figure 3 5 12 slot dimm numbering on page 3 7 for details 35
- Figure 4 4 intel 5500 tylersburg chipset block diagram 35
- Gbx connectors for power and logic to backplane 35
- Ich10r south bridge chip 35
- Infiniband connectors for infiniband cards 35
- Intel 5500 tylersburg north bridge chip 35
- Item description 35
- J1btn1 raid 5 key connector 35
- Kvm module 35
- Lga 1366 cpu1 socket 35
- Lga 1366 cpu2 socket 35
- Lsi 2008 sas2 controller 35
- Onboard battery 35
- Table 4 4 b8dt6 mainboard layout 35
- Tylersburg 35
- Cmos clear 36
- Jumpers 36
- Sbi 7126t s6 blade module user s manual 36
- 3 blade unit components 37
- Chapter 4 blade module features 37
- Figure 4 5 exploded view of sbi 7126t s6 blade module 37
- Item description 37
- Main components of the sbi 7126t s6 blade module are shown in figure 4 5 and described in table 4 5 37
- Table 4 5 main components of sbi 7126t s6 blade module 37
- Hard disk drives 38
- Memory support 38
- Sbi 7126t s6 blade module user s manual 38
- Chapter 5 raid setup procedure 39
- Important notes 39
- 1 introduction 41
- Chapter 6 bios 41
- How to change the configuration data 41
- Starting the setup utility 41
- System bios 41
- 2 bios updates 42
- Flashing bios 42
- Sbi 7126t s6 blade module user s manual 42
- 3 running setup 43
- Chapter 6 bios 43
- 4 main bios setup 44
- Figure 6 1 main setup menu screen 44
- Sbi 7126t s6 blade module user s manual 44
- 5 advanced setup 45
- Chapter 6 bios 45
- Figure 6 2 advanced setup menu 45
- Table 6 1 main bios setup menu options 45
- Options for pir settings are displayed by highlighting the setting option using the arrow keys and pressing 46
- Sbi 7126t s6 blade module user s manual 46
- Sub menu description 46
- Table 6 2 advanced setup menu options 46
- Table 6 2 describes all sub menus found in the 46
- The items with a triangle beside them are sub menus that can be accessed by highlighting the item and pressing 46
- Chapter 6 bios 47
- Menu option description 47
- Table 6 3 cpu and clock configuration sub menu 47
- Table 6 4 ide configuration menu 47
- Menu option description 48
- Sbi 7126t s6 blade module user s manual 48
- Table 6 4 ide configuration menu continued 48
- Table 6 5 pcipnp configuration sub menu 48
- Chapter 6 bios 49
- Menu option description 49
- Table 6 6 superio configuration sub menu 49
- Table 6 7 chipset configuration sub menu 49
- Menu option description 50
- Sbi 7126t s6 blade module user s manual 50
- Table 6 7 chipset configuration sub menu continued 50
- Chapter 6 bios 51
- Menu option description 51
- Table 6 7 chipset configuration sub menu continued 51
- Table 6 8 acpi configuration sub menu 51
- Menu option description 52
- Sbi 7126t s6 blade module user s manual 52
- Table 6 10 event log configuration sub menu 52
- Table 6 11 ipmi configuration sub menu 52
- Table 6 9 ahci configuration sub menu 52
- Chapter 6 bios 53
- Menu option description 53
- Table 6 11 ipmi configuration sub menu continued 53
- Menu option description 54
- Sbi 7126t s6 blade module user s manual 54
- Table 6 12 mps configuration sub menu 54
- Table 6 13 pci express configuration sub menu 54
- Table 6 14 smbios configuration sub menu 54
- Table 6 15 remote access configuration sub menu 54
- 6 security 55
- Chapter 6 bios 55
- Figure 6 3 security setup menu 55
- Menu option description 55
- Table 6 16 system health monitor sub menu 55
- All security bios settings are described in table 6 17 below 56
- Choose security from the ami bios setup utility main menu with the arrow keys to bring up the 56
- Menu figure 6 3 security setting options are displayed by highlighting the setting using the arrow keys and pressing 56
- Menu option description 56
- Sbi 7126t s6 blade module user s manual 56
- Table 6 17 security menu options 56
- 7 boot 57
- Chapter 6 bios 57
- Figure 6 4 boot setup menu 57
- Table 6 18 boot setup menu options 57
- Menu option description 58
- Sbi 7126t s6 blade module user s manual 58
- Table 6 18 boot setup menu options continued 58
- 8 exit 59
- Chapter 6 bios 59
- Choose 59
- Figure 6 5 exit setup menu 59
- From the ami bios setup utility main menu with the arrow keys to display the 59
- Menu figure 6 5 all exit bios settings are described in table 6 19 below 59
- Menu option description 59
- Table 6 19 exit menu options 59
- 9 hardware health information 60
- Cpu temperature 60
- Sbi 7126t s6 blade module user s manual 60
- Chapter 6 bios 61
- System temperature 61
- Voltage monitoring 61
- A 1 bios post messages 63
- Appendix a bios post codes 63
- Bios message description 63
- During the power on self test post the bios will check for problems if a problem is found the bios will activate an alarm or display a message the following is a list of such bios messages 63
- Table a 1 bios post messages 63
- Bios message description 64
- Sbi 7126t s6 blade module user s manual 64
- Table a 1 bios post messages continued 64
- A 2 bios post codes 65
- Bios message description 65
- Table a 1 bios post messages continued 65
- This section lists the post power on self test codes for the ami bios post codes are divided into two categories recoverable and terminal 65
- H disable non maskable interrupt nmi 66
- H get cpu type 66
- H verify real mode 66
- If a terminal type of error occurs bios will shut down the system before doing so bios will write the error to port 80h attempt to initialize video and write the error in the top left corner of the screen 66
- One long and two short beeps video configuration error 66
- One repetitive long beep no memory detected 66
- Post code description 66
- Recoverable post errors 66
- Sbi 7126t s6 blade module user s manual 66
- Table a 2 terminal post errors 66
- Terminal post errors 66
- The following is a list of codes that may be written to port 80h 66
- When a recoverable type of error occurs during post the bios will display an post code that describes the problem bios may also issue one of the following beep codes 66
- Post code description 67
- Table a 2 terminal post errors continued 67
- Post code description 68
- Sbi 7126t s6 blade module user s manual 68
- Table a 2 terminal post errors continued 68
- Post code description 69
- Table a 2 terminal post errors continued 69
- D2h unknown interrupt 70
- Post code description 70
- Sbi 7126t s6 blade module user s manual 70
- Table a 2 terminal post errors continued 70
- Table a 3 boot block flash rom terminal post errors 70
- The following are for the boot block in flash rom 70
- Disclaimer 73
Похожие устройства
- Supermicro CSE-745TQ-800B Инструкция по эксплуатации
- Supermicro SYS-6026T-3RF Инструкция по эксплуатации
- Supermicro CSE-745TQ-R800B Инструкция по эксплуатации
- Supermicro X8DTL-iF Инструкция по эксплуатации
- Supermicro X8DTN+ Инструкция по эксплуатации
- Supermicro X8DTN+-F Инструкция по эксплуатации
- Supermicro X8STE Инструкция по эксплуатации
- Supermicro SYS-5017C-MTF Инструкция по эксплуатации
- Supermicro CSE-836E1-R800B Инструкция по эксплуатации
- Supermicro CSE-846TQ-R900B Инструкция по эксплуатации
- Supermicro sys-8027r-7rft+ Инструкция по эксплуатации
- Supermicro cse-745tq-r1200b Инструкция по эксплуатации
- Supermicro cse-523l-520b Инструкция по эксплуатации
- Supermicro sys-6027r- wrf Инструкция по эксплуатации
- Merrylock 5550A Инструкция по эксплуатации
- Merrylock 075 Инструкция по эксплуатации
- Merrylock 0115A Инструкция по эксплуатации
- Merrylock 015 Инструкция по эксплуатации
- Merrylock 095 Инструкция по эксплуатации
- Merrylock Cover Pro Auto III Инструкция по эксплуатации