Supermicro sys-6027r-3rf4+ [64/122] 4 and the table on the right for pin

Supermicro sys-6027r-3rf4+ [64/122] 4 and the table on the right for pin
5-18
SUPERSERVER 6027R-3RF4+ User's Manual
Information LED
Connect an LED to the OH connection
on pins 7 and 8 of JF1 for UID and to
provide advanced warning of chassis
overheating and fan fail. Refer to p.
5-4 and the table on the right for pin
de nitions. Refer to Chapter 3 for fur-
ther details on the control panel LED.
HDD LED
The HDD LED connection is located
on pins 13 and 14 of JF1. This LED
is used to display all IDE/SAS/SATA
activity. See the p. 5-4 and table on
the right for pin de nitions.
OH/Fan Fail/UID LED
Pin De nitions (JF1)
Pin# De nition
7 Vcc
8 Ground
NIC2 LED
Pin De nitions (JF1)
Pin# De nition
9 Vcc
10 Ground
HDD LED
Pin De nitions (JF1)
Pin# De nition
13 Vcc
14 HD Active
NIC2 (JLAN2) LED
The LED connections for JLAN2 are
on pins 9 and 10 of JF1. Attach an
LED cable to display network activity.
See p. 5-4 and the table on the right
for pin de nitions.
NIC1 LED
Pin De nitions (JF1)
Pin# De nition
11 Vcc
12 Ground
NIC1 (JLAN1) LED
The LED connections for JLAN1 are
on pins 11 and 12 of JF1. Attach an
LED cable to display network activity.
See p. 5-4 and the table on the right
for pin de nitions.
OH/Fan Fail Indicator
Status
State De nition
Off Normal
On Overheat
Flash-
ing
Fan Fail
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. Refer
to p. 5-4 and the table on the right for
pin de nitions.
PWR Fail LED
Pin De nitions (JF1)
Pin# De nition
5 Vcc
6 Ground

Содержание