Ihealth bp7 Инструкция по эксплуатации онлайн [7/16] 167323
7
GENERAL SAFETY AND PRECAUTIONS
1. Read all of the information in the Owner’s Manual and other provided
instructions before operating the unit.
2. Consult your physician for any of the f ollowing situations:
a)The application of the cuff over a wound or inflamed area.
b)The application of the cuff on any limb with intravascular access or therapy,
or an arterio-venous (A-V) shunt.
c)The application of the cuff on the wrist on the side of a mastectomy.
d)Simultaneous use with other medical monitoring equipment on the same
limb.
e)The blood circulation of the user needs to be checked.
3. Do not use this product in a moving vehicle as this may result in inaccurate
measurements.
4. Blood pressure measurements determined by this product are equivalent to
those obtained by professional healthcare practitioners using the
cuff/stethoscope auscultation method within the limits prescribed by the
American National Standard, Electronic or Automated Sphygmomanometer.
5. When a call comes in during the measurement, the measurement process
will be terminated automatically. It is recommended that the iOS device be
set in Airplane mode during measurement to avoid strong magnetism
interference.
6. If Irregular Heartbeat (IHB) is detected during the measurement procedure,
the IHB symbol will be displayed. Under this condition, the Wireless Blood
Pressure Wrist Monitor can keep functioning, but the results may be
inaccurate. Please consult your physician for accurate assessment.
There are 2 conditions under which the signal of IHB will
be displayed:
1)The coefficient of variation (CV) of pulse period >25%.
2)The difference of adjacent pulse period ≥0.14s and the numbe r of such
pulse takes more than 53 percent of the total number of pulses.
7. Please do not use any other cuff other than that supplied by the
manufacturer as this may result in measurement errors and a biocompatible
hazard.
8. Information regarding potential electromagnetic or other interference
between the blood pressure monitor and other devices together with advice
regarding avoidance of such interference, please see ELECTROMAGNETIC
COMPATIBILITY INFORMATION. It is suggested that the blood pressure
monitor be kept 10 meters away from other wireless devices, such as WLAN
unit, microwave oven, etc.
9. This product should not be used as a USB device.
10.This product is verified by auscultatory method. It is recommended that you
check Annex B of ANSI/AAMI SP-10:2002+A1:2003+A2:2006 for verification
method details if needed.
11.If the determined blood pressure (systolic or diastolic) is outside the rated
Содержание
- Account set up and registration follow the on screen instructions to register and set up your personal account 4
- Charge battery prior first time use connect the monitor to a usb port using the charging cable provided until the green indicator light stabilizes 4
- Connect to ios device via bluetooth 4
- Download the free ihealth app prior to first use download and instal 4
- From the app store 4
- Ihealth myvital 4
- Monitor status bluetooth indicator 4
- Set up procedures 4
- Blood pressure can be affected by the position of the cuff and your physiologic condition it is very important that you keep your wrist at heart level 5
- Measurement procedures 5
- On apply the cuff follow the measurement instructions and 5
- Press the start stop button to stop measurement press the start stop button for 2 seconds to turn off the monitor manually 5
- Taking measurements with multiple ios devices turn off the bluetooth on the last used ios device if the auto connect option is enabled in your app then follow the set up instructions in the quick start guide 5
- Battery handling and usage 8
- Monitor status status indicator 8
- Range specified in part specifications the app will immediately display a technical alarm on screen in this case consult a physician or ensure that proper measurement procedures are followed the technical alarm is preset in the factory and cannot be adjusted or inactivated this technical alarm is assigned as low priority according to iec 60601 1 8 the technical alarm is non latching and does not need to be reset 12 a medical ac adapter with an output of dc 5 v and complies with iec 60601 1 ul 60601 1 and iec 60601 1 2 en 60601 1 2 is suitable for this monitor such as asp5 05010002ju input 100 240v 50 60hz 200ma output dc 5 v 1 a please note that the monitor jack size is usb mini b 8
- Problem possible cause solution 9
- The monitor cable battery and cuff must be disposed of according to local regulations at the end of their usage 9
- Troubleshooting 9
- Electromagnetic compatibility information 13
- Iec 60601 1 2006 medical electrical equipment part 1 general requirements for safety iec 60601 1 2 2007 medical electrical equipment part 1 general requirements for safety collateral standard electromagnetic compatibility requirements and tests en 1060 1 1995 a1 2002 a2 2009 non invasive sphygmomanometers part 1 general requirements en 1060 3 1997 a1 2005 a2 2009 non invasive sphygmomanometers part 3 supplementary requirements for electro mechanical blood pressure measuring systems ansi aami sp 10 2002 a1 2003 a2 2006 aami ansi 80601 2 30 2009 iec 80601 2 30 2009 cor 010 en 80601 2 30 2010 medical electrical equipment part 2 30 particular requirements for the basic safety and essential performance of automated non invasive sphygmomanometers 13
Похожие устройства
- Yealink TA410 Инструкция по эксплуатации
- Ihealth bp5 Инструкция по эксплуатации
- Ihealth wireless activity and sleep tracker Инструкция по эксплуатации
- Ihealth hs5, bluetooth, wifi, для apple iphone/ipad/ipod Инструкция по эксплуатации
- Iconbit toucan omnicast Инструкция по эксплуатации
- Yealink TA410 Руководство по подключению
- Атлант 6325-101 Инструкция по эксплуатации
- Zanussi zck 9552 g1w Инструкция по эксплуатации
- Zanussi zck 9540 g1w Инструкция по эксплуатации
- Yealink TA410 Инструкция по эксплуатации
- Yealink TA200 Инструкция по эксплуатации
- Yealink TA200 Руководство по подключению
- Yealink TA200 Технические характеристики
- Yealink TA100 Инструкция по эксплуатации
- Yealink TA100 Руководство по подключению
- Yealink TA100 Технические характеристики
- Yealink TG1600 Инструкция по эксплуатации
- Yealink TG1600 Руководство администратора
- Yealink TG1600 Технические характеристики
- Yealink TG800 Инструкция по эксплуатации
Скачать
Случайные обсуждения