Maintenance
308778U 13
Cleaning or Servicing the Meter
Chamber
1. Follow the Pressure Relief Procedure, on page
10. Then close the fluid shut-off valve on each side
of the meter.
2. Disconnect the cable from the electronic sensor
device.
3. Disconnect both fluid line fittings and remove the
meter from the fluid line.
4. Loosen the two screws and remove the electronic
sensor device from the flow meter upper housing.
See the Parts drawings, pages 16-18.
5. Loosen the screws. Keep a few threads of two
opposing bolts engaged to minimize the torque
stress on the shafts when you separate the meter
housings.
6. Hold onto the upper housing and gently tap the
opposing bolts to separate the lower housing.
7. Remove and inspect the gears and shafts. Clean
the meter parts with solvent.
8. Reassemble the gears and shafts into the lower
housing in the position they were removed from.
Check the gears for free and easy rotation.
9. Make sure the two locating pins are in place.
10. Assemble the two meter housings, making sure to
keep them parallel to each other.
11. Install the screws. Tighten them oppositely and
evenly, to 12 ft-lb (16 N•m). Do not over-tighten.
12. After re-assembling the meter, test the gear rotation
by applying a brief air blast to the meter inlet. You
should clearly hear the gears spin.
13. Set the electronic sensor on the upper housing and
tighten the two screws hand-tight, about 27-57 in-lb
(3.1-6.4 N•m). Do not over-tighten.
14. Attach fluid lines and sensor cable.
15. Open fluid shut-off valves.
Replacing the Electronic Sensor
1. Follow the Pressure Relief Procedure, on page
10. Then close the fluid shut-off valve on each side
of the meter.
2. Disconnect the cable from the electronic sensor
device.
3. Loosen the two screws and remove the electronic
sensor device from the flow meter upper housing.
See the Parts drawings, pages 16-18.
4. Set the electronic sensor on the upper housing and
tighten the two screws hand-tight, about 27-57 in-lb
(3.1-6.4 N•m). Do not over-tighten.
5. Attach sensor cable.
NOTICE
Clean and service the meter at a clean workbench.
Use only lint-free cloth on parts.
Installing and servicing this equipment requires
access to parts that may cause electric shock or other
serious injury if the work is not performed properly. Do
not install or service this equipment unless you are
trained and qualified.
Use only genuine Graco replacement parts. Substitu-
tion of components may impair intrinsic safety. This
could result in a failure which causes serious injury
and/or substantial property damage.
NOTICE
To avoid damaging the shafts, keep the housings par-
allel to each other when separating them; do not rock
the housings from side to side. Do not use chisels or
screwdrivers to split and pry apart the housings.
Содержание
- Instructions parts p.1
- Important safety instructions p.1
- For precise metering of plural component fluids or solvents depending on model for professional use only p.1
- Volumetric fluid flow meter p.1
- Contents p.2
- Solvent meter kit p.3
- Meter models p.3
- Meter kits p.3
- Low pressure fluid meters p.3
- High pressure solvent meter p.3
- High pressure fluid meters p.3
- G3000 fluid meter kits p.3
- Warnings p.4
- Installation p.7
- Installing the flow meter p.7
- Dust and foreign matter p.7
- Atex certificate its12atex27565x system assembly certificate p.8
- Intrinsically safe installation requirements p.8
- Intrinsically safe installation p.8
- Meter cables and adaptor p.9
- Grounding p.9
- Recommended usage p.10
- Pressure relief procedure p.10
- Operation p.10
- Flow volume range p.10
- Flow meter function p.10
- Checking the meter accuracy p.10
- Troubleshooting p.11
- Maintenance p.12
- Flushing p.12
- Residue build up on the meter gears p.12
- Replacing the electronic sensor p.13
- Cleaning or servicing the meter chamber p.13
- Cleaning or servicing the solvent meter p.14
- V827 g3000hr meter kit p.15
- V804 g3000 meter kit p.15
- S3000 solvent meter kit p.15
- Flow meter kits for promix 2ks wall fluid panel p.15
- G3000 meter p.16
- G3000hr meter p.16
- Bare meter assemblies p.16
- G250hr meter p.17
- G250 meter p.17
- Solvent meter assembly p.18
- S3000 meter p.18
- Part nos 289813 and 289814 p.20
- Part nos 249426 and 249427 p.20
- Mounting holes bottom p.20
- G3000 and g3000hr p.20
- G250 and g250hr p.20
- Dimensions p.20
- Solvent meter p.21
- Part no 258718 p.21
- Part no 15u749 p.21
- Mounting holes bottom p.21
- Kit mounting bracket p.21
- Volumetric fluid flow meters p.22
- Technical data p.22
- Pressure drop curve p.23
- To place an order contact your graco distributor or call to identify the nearest distributor phone 612 623 6921 or toll free 1 800 328 0211 fax 612 378 3505 p.24
- Graco headquarters minneapolis international offices belgium china japan korea p.24
- For the latest information about graco products visit www graco com p.24
- Graco standard warranty p.24
- Graco information p.24
- Graco inc and subsidiaries p o box 1441 minneapolis mn 55440 1441 usa copyright 1997 graco inc all graco manufacturing locations are registered to iso 9001 www graco com revised november 2015 p.24
Похожие устройства
-
Graco EM8, жесткий носик, 1/2" NPT 25C903Инструкция к Graco EM8 25C903 -
Graco CoriolisСхема сборки -
Graco CoriolisИнструкция по эксплуатации -
Graco HG6000HRТехнические характеристики -
Graco HG6000HRИнструкция по эксплуатации -
Graco HG6000Технический паспорт -
Graco HG6000Инструкция по эксплуатации -
Graco S3000Технические характеристики -
Graco G3000HRТехнические характеристики -
Graco G3000HRИнструкция по эксплуатации -
Graco G3000Технические характеристики -
Graco G3000Инструкция по эксплуатации