Moxa PT-7528-16MSC-8TX-4GSFP-HV [83/116] Configuring ieee 802 x

Moxa PT-7528-8SSC-16TX-4GSFP-WV-WV [83/116] Configuring ieee 802 x
PT-7528 Series Advanced Settings
4-63
Configuring IEEE 802.1X
Database Option
Setting Description Factory Default
Local
(Max. of 32 users)
Select this option when setting the Local User Database as the
authentication database.
Local
Radius Select this option to set an external RADIUS server as the
authentication database. The authentication mechanism is
EAP-MD5.
Local
Radius, Local
Select this option to make using an external RADIUS server as
the authentication database the first priority. The
authentication mechanism is EAP-
MD5 The first priority is to set
the Local User Database as the authentication database.
Local
Radius Server
Setting
Description
Factory Default
IP address or domain
name
The IP address or domain name of the RADIUS server local host
Server Port
Setting Description Factory Default
Numerical
The UDP port of the RADIUS server
1812
Shared Key
Setting Description Factory Default
alphanumeric (Max. of
40 characters)
A key to be shared between the external RADIUS server and
Moxa switch. Both ends must be configured to use the same
key.
None
Re-Auth
Setting Description Factory Default
Enable/Disable Select enable to require re-authentication of the client after a
preset time period of no activity has elapsed.
Disable
Re-Auth Period
Setting Description Factory Default
Numerical
(60 to 65535 sec.)
Specify how frequently the end stations need to reenter
usernames and passwords in order to stay connected.
3600