Moxa IKS-G6524A-4GTXSFP-HV-HV [171/173] Warning notification port event

Moxa IKS-G6524A-4GTXSFP-HV-HV [171/173] Warning notification port event
Moxa Command Line Interface (FW_5.x) Commands
2-161
Error
messages
Name shoud be assigned after VLAN member port setting
Length of VLAN name is at most 31 character
Related
commands
vlan mode
warning-notification port-event
Use warning-notification port-event interface configuration commands to enable the port warning events
trigger to email, relay, syslog or trap. Use no form of this command to disable it.
Commands
warning-notification port-event {event { link-on | link-off | traffic-overload rxThreshold duration} |
action action-index |severity severity-level | active}
no warning-notification port-event {event { link-on | link-off | traffic-overload} | active}
Syntax
Description
warning-notification Warning notification
port-event Port event setting
event Select and configure event
link-on Link ON
link-off Link OFF
traffic-overload Traffic overloading
rx-threshold 0 ~ 100
duration 1 ~ 300
action
Enable Action setting
action-index 0 ~ 31
severity Severity setting
severity-level 0 ~ 7
active Activate
Defaults N/A
Command
Modes
Interface configuration
Usage
Guidelines
action-index as follow,
Trap only(1), Email only(2), Trap+Email(3), Syslog only(4), Trap+Syslog(5),
Email+Syslog(6), Trap+Email+Syslog(7), Relay1 only(8), Trap+Relay1(9),
Email+Relay1(10), Trap+Email+Relay1(11), Syslog+Relay1(12), Trap+Syslog+Relay1(13),
Email+Syslog+Relay1(14), Trap+Email+Syslog+Relay1(15), Relay2 only(16),
Trap+Relay2(17), Email+Relay2(18), Trap+Email+Relay2(19), Syslog+Relay2(20),
Trap+Syslog+Relay2(21), Email+Syslog+Relay2(22), Trap+Email+Syslog+Relay2(23),
Relay1+Relay2(24), Trap+Relay1+Relay2(25), Syslog+Relay1+Realy2(28),
Email+Syslog+Relay1+Relay2(30), Trap+Email+Syslog+Relay1+Relay2(31), None(0)
severity-level as follow,
Emergency(0), Alert(1), Critical(2), Error(3), Warning(4), Notice(5), Information(6),
Debug(7)
Examples
MOXA(config-if)#warning-notification port-event event traffic-overload 30 150