Moxa AWK-1121-PoE-EU-T [8/13] Attention

Moxa AWK-1121-PoE-EU [8/13] Attention
- 8 -
Arrester Accessories
SA-NMNF-01: Surge arrester, N-type (male) to N-type (female)
SA-NFNF-01: Surge arrester, N-type (female) to N-type (female)
Wiring the Redundant Power Inputs
The 4-contact terminal block connector on the AWK-1121’s top panel is
used for the AWK-1121’s two DC inputs. The top and front views of the
terminal block connector are shown here.
Top View
Front View
STEP 1: Insert the negative/positive DC wires
into the
V-/V+ terminals.
STEP 2:
To keep the DC wires from pulling
loose,
use a small flat
-blade screwdriver to
tighten the
wire
-clamp screws on the front of the terminal
block connector.
STEP 3:
Insert the plastic terminal block
connector prongs into the terminal block
receptor, which is
located on the AWK-1121s t
op
panel.
ATTENTION
If the AWK
-1121 is connected to a motor or other similar type
of
equipment, be sure to use power isolation protection. Before
connecting the
AWK-1121
to the DC power inputs, make sure the
DC power source voltage is stable.

Похожие устройства