Moxa UC-8416-CE [10/48] Inserting a compactflash card

Moxa UC-8416-CE [10/48] Inserting a compactflash card
UC-8400 WinCE Introduction
1-6
Inserting a CompactFlash Card
The UC-8410/8416/8418/8430-CE are equipped with a CompactFlash slot of type II that supports cards of both
types I and II. A mass storage card is considered to be a standard attachment to the computer. When an empty
mass storage card is inserted into the slot, the computer automatically formats it to the FAT system. This
process takes a few minutes to complete. When a mass storage card is inserted, the
UC-8410/8416/8418/8430-CE create a directory named HardDiskunder the root directory and the newly
created directory serves as a link to the storage. The UC-8410/8416/8418/8430-CE does not support PNP (plug
and play) and hot swap for CompactFlash storage devices. Users must switch off the power and then insert the
CompactFlash storage device in the slot. When the power is switched on again, the
UC-8410/8416/8418/8430-CE will detect the CompactFlash storage device. Be sure to shut off the power
before removing the CompactFlash storage device.
The following table describes the compatible CompactFlash storage devices that have been tested and found to
be compatible with the UC-8410/8416/8418/8430-CE computers.
Vendor Device Name Size
ScanDisk
Ultra
1 GB
Transcend Compact Flash 80X 512 MB
Apacer Photo CIENO 2 GB
Unigen Compact Flash card 128 MB
Inserting a USB Mass Storage Device
When an empty USB storage device is plugged into the USB slot on the UC-8410/8416/8418/8430-CE’s rear
panel, the computer automatically formats device to the FAT system.
When the first USB mass storage device is plugged in, a directory named StorageDiskis created in the
internal file system under the root directory as a link to the storage device. The directory created for the second
USB device isStorageDisk2.”
RS-232/422/485 Serial Ports
The UC-8410/8416/8418/8430-CE computers come with 8 high performance serial ports named from “COM3”
to “COM10”. All of them are designed to provide reliability, high-speed and 3-in-1 (i.e., RS-232, RS-422, and
RS-485) operation mode switch for your diverse applications. Each of these ports supports baudrate settings
up to 921600 bps.
You can use the interface utility setinterface.exe to change or display your port interface. Ex.: Type
“setinterface COM3: 1” to change the port interface to RS-485 2W.
\>setinterface
ModelName:UC-8410/8416/8418/8430-CE
COM3: = RS-232
COM4: = RS-232
COM5: = RS-232
COM6: = RS-232
COM7: = RS-232
COM8: = RS-232
COM9: = RS-232
COM10: = RS-232
\> setinterface –h
SetInterface [COMx:] [mode]
mode: 0 (RS232)
mode: 1 (RS485 2 Wire)