Moxa UC-8416-CE [13/48] Powering on the uc 8410 8416 8418 8430
![Moxa UC-8410-CE [13/48] Powering on the uc 8410 8416 8418 8430](/views2/1199777/page13/bgd.png)
UC-8400 WinCE Getting Started
2-2
Powering on the UC-8410/8416/8418/8430
To boot up the system, connect the power source to the power input located on the computer’s rear panel. It
takes about 5 seconds for the system to boot up. You will hear a clear “BEEP” sound when the boot up
procedure is finished. Once the system is ready, the “Ready” LED will light up and stay on until you shut down
the computer.
Resetting the UC-8410/8416/8418/8430-CE
Computer
Warm-Start: When powering on, push the “Reset” button briefly (for less than1 second). The computer will
reboot automatically.
Cold-Start: Switch the power off and then on again. The computer will reboot automatically.
Reset to Factory Defaults (Configuration only): If the computer is not working properly and you would like
to reset it to factory default settings, press and hold the “Reset” button for 5 seconds as the operating system
is starting up. The buzzer sounds while the factory default settings are being loaded. After the factory default
settings have finished loading, the computer will reboot automatically. Do not confuse this action with
“Warm-Start.”
Reset to Factory Defaults (Configuration and file system): If the computer will not start up, you must go
to the Boot Loader and format the flash storage. Once the flash storage has been reformatted, restart the
computer.
Boot Loader
Three functions are provided to enhance the stability of the operating system.
• Reset to default—This function allows users to load the factory default into the
UC-8410/8416/8418/8430.
• Format storage flash—CE 6.0 is a FAT-based system. The system cannot work well when the FAT table is
crashed. This function allows users to format the file system and reboot the UC-8410/8416/8418/8430.
• Firmware upgrade—The latest firmware can be downloaded from Moxa’s website. See Appendix A for
instructions on how to upgrade the firmware.
Use the following procedure to access the boot loader menu from the serial console:
1. Power off the UC-8410/8416/8418/8430-CE.
2. Connect the serial console cable to your PC.
3. Go to [Start] [Programs] [Accessories] [Communication] [Terminal] to create a new
terminal. Use these settings: Baudrate = 115200, Hardware Flow Control = None, Data bits = 8, Parity =
None, Stop bits = 1, Terminal = VT100.
4. Activate this terminal window on your PC.
5. Hold down the “DEL” key.
6. Power on the UC-8410/8416/8418/8430-CE.
Operating the UC-8410/8416/8418/8430-CE
Computer via the Serial Console
The serial console port gives users a convenient way of connecting the development workstation to the console
utility of the target computer. This method is particularly useful when using the target computer for the first
time.
Содержание
- Fifth edition january 2012 1
- Uc 8410 8416 8418 8430 wince user s manual 1
- Www moxa com product 1
- Copyright notice 2
- Disclaimer 2
- Technical support contact information 2
- Trademarks 2
- Uc 8410 8416 8418 8430 wince user s manual 2
- Www moxa com support 2
- Table of contents 3
- Introduction 5
- Model descriptions and package checklist 6
- Overview 6
- Uc 8400 wince introduction 6
- Uc 8410 ce 6
- Uc 8410 t ce 6
- Uc 8416 ce 6
- Uc 8416 t ce 6
- Uc 8418 ce 6
- Uc 8418 t ce 6
- Uc 8430 ce 6
- Uc 8430 t ce 6
- Application development environment 7
- Networking and communications capabilities 7
- Software specifications 7
- Uc 8400 wince introduction 7
- Graphics and multimedia tools uc 8430 ce only 8
- Supported servers and daemons 8
- Uc 8400 wince introduction 8
- Audio uc 8430 ce only 9
- Dual display uc 8430 ce only 9
- Firmware build versions 9
- Hive based registry not ram based 9
- Memory and file systems 9
- Uc 8400 wince introduction 9
- Inserting a compactflash card 10
- Inserting a usb mass storage device 10
- Rs 232 422 485 serial ports 10
- Setinterface h setinterface comx mode mode 0 rs232 mode 1 rs485 2 wire 10
- Uc 8400 wince introduction 10
- Getting started 12
- Boot loader 13
- Operating the uc 8410 8416 8418 8430 ce computer via the serial console 13
- Powering on the uc 8410 8416 8418 8430 13
- Resetting the uc 8410 8416 8418 8430 ce computer 13
- Uc 8400 wince getting started 13
- Changing the network settings 14
- Uc 8400 wince getting started 14
- Netconfig lan1 interface configuration ip address 192 68 subnet mask 255 55 55 gateway 192 68 54 dns 192 68 lan2 interface configuration ip address 192 68 27 subnet mask 255 55 55 gateway dns 15
- Netconfig n lan1 i 192 68 m 255 55 55 g 192 68 54 d 192 68 15
- Uc 8400 wince getting started 15
- Virtual private network vpn uc 8430 ce only 15
- Dir b nandflash my documents program files temp windows 16
- Operating the uc 8410 8416 8418 8430 ce computers via telnet 16
- Uc 8400 wince getting started 16
- User group management 16
- Useradd g yyyy group yyyy has been added 16
- Userdel g yyyy group yyyy has been removed 16
- Adjusting the system time 17
- Adjusting the time zone 17
- Starting and stopping services 17
- Time t 4 02 04 pm 17
- Uc 8400 wince getting started 17
- Useradd g telnetd xxxx user xxxx is existent group telnetd is existent user xxxx has been added to group yyyy 17
- Useradd xxxx user xxxx has been added 17
- Userdel g yyyy xxxx user xxxx has been removed from group yyyy 17
- Userdel xxxx user xxxx has been deleted 17
- Troubleshooting network connectivity 18
- Simple network management protocol snmp 19
- Snmp agent 19
- Snmp manager 19
- Accessing files through file sharing 20
- Uc 8400 wince getting started 21
- Uc 8400 wince getting started 22
- Management tools 23
- Serial port configuration 24
- System information 24
- Uc 8400 wince management tools 24
- Process thread monitoring control 25
- Services monitoring control 25
- Uc 8400 wince management tools 25
- Display 26
- Uc 8400 wince management tools 26
- User group management 26
- Auto launch configuration 27
- Uc 8400 wince management tools 27
- Uc 8400 wince management tools 28
- Web server configuration 28
- Dhcp allocator configuration 29
- Uc 8400 wince management tools 29
- Uc 8400 wince management tools 30
- Web based management system 31
- Networking server configuration 32
- System information 32
- Uc 8400 wince web based management system 32
- Launching processes automatically 33
- Process thread monitoring control 33
- Serial port configuration 33
- Uc 8400 wince web based management system 33
- Binary text file management 34
- Services monitoring control 34
- Uc 8400 wince web based management system 34
- A firmware upgrade procedure 35
- Firmware upgrade procedure 35
- Uc 8400 wince firmware upgrade procedure 36
- Uc 8400 wince firmware upgrade procedure 37
- Application development with the sdk and software libraries 38
- B application development with the sdk and software libraries 38
- Developing an application with vs2005 39
- Installing the sdk 39
- Uc 8400 wince application development with the sdk and software libraries 39
- Visual c library 39
- Uc 8400 wince application development with the sdk and software libraries 40
- Buzzer 41
- Uc 8400 wince application development with the sdk and software libraries 41
- Watchdog 41
- Canbus uc 8418 only 42
- Uc 8400 wince application development with the sdk and software libraries 42
- Uc 8400 wince application development with the sdk and software libraries 43
- Structure of canmsg 44
- Typedef struct _canmsg unsigned int identifier unsigned int flags unsigned int length the length of data unsigned char data8 canmsg structure of canprm typedef struct _canprm unsigned int bus_timing the bus speed in khz 32 bit integer default is 1000 44
- Uc 8400 wince application development with the sdk and software libraries 44
- Net compact framework library 45
- Visual c examples 45
- Uc 8400 wince application development with the sdk and software libraries 46
- Buzzer 47
- Uc 8400 wince application development with the sdk and software libraries 47
- Watchdog 47
- Uc 8400 wince application development with the sdk and software libraries 48
- Visual c examples 48
Похожие устройства
- Moxa UC-8416-CE Руководство по аппаратной части
- Moxa UC-8416-CE Технические характеристики
- Moxa UC-8416-CE Руководство по быстрой установке
- Moxa UC-8416-CE Руководство по работе с утилитой Moxa Device Manager
- Moxa UC-8416-LX Инструкция по эксплуатации
- Moxa UC-8416-LX Руководство по аппаратной части
- Moxa UC-8416-LX Технические характеристики
- Moxa UC-8416-LX Руководство по быстрой установке
- Moxa UC-8416-LX Руководство по работе с утилитой Moxa Device Manager
- Moxa UC-8416-T-LX Инструкция по эксплуатации
- Moxa UC-8416-T-LX Руководство по аппаратной части
- Moxa UC-8416-T-LX Руководство по быстрой установке
- Moxa UC-8416-T-LX Технические характеристики
- Moxa UC-8416-T-LX Руководство по работе с утилитой Moxa Device Manager
- Moxa UC-8418-CE Инструкция по эксплуатации
- Moxa UC-8418-CE Технические характеристики
- Moxa UC-8418-CE Руководство по аппаратной части
- Moxa UC-8418-CE Руководство по быстрой установке
- Moxa UC-8418-CE Руководство по работе с утилитой Moxa Device Manager
- Moxa UC-8418-T-CE Инструкция по эксплуатации