Moxa VPort 26A-1MP System Configuration
4-25
Once the Http Alarm is triggered, the VPort will send the following HTTP commands to the HTTP event servers.
GET CGI_Name?address=<Hostname or IP Address>&[Custom CGI] HTTP/1.0\r\n
User-Agent: IP camera V1.1\r\n
[Authorization: Basic <Buse64(username:password)>\r\n]
Host: <HTTP Server IP Address>\r\n
Connection: Keep-Alive\r\n
\r\n
ModBus/TCP
Modbus is a serial communications protocol which is often used to connect a supervisory computer with a
remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems. To transmit Modbus
over a TCP/IP network, a standard Modbus/TCP protocol is provided. With the support of the Modbus/TCP
protocol, the SCADA/HMI system can directly communicate with the VPort to acquire its operational status.
Setting Description Factory Default
Enable Modbus/TCP Enable the Modbus/TCP protocol Enable
NOTE
For Modbus address table, please refer to the Modbus_Address_Define.pdf. You can find it on the software CD
or the download center of the Moxa website.
The VPort 26A-1MP supports advanced IEEE 802.1X network authentication function. There are three types of
802.1X supported: EAP-MD5, EAP-PEAP/MSCHAPv2 and EAP-TLS. The Administrator should choose the
appropriate type base on the network system situation.
EAP-MD5
EAP-PEAP/MSCHAPv2