Moxa VPort 36-1MP-IVA [18/78] Wiring requirements

Moxa VPort 36-1MP-T [18/78] Wiring requirements
VPort 36-1MP Getting Started
2-8
Wiring Requirements
SAFETY FIRST
Be sure to disconnect the power cord before installing and/or wiring your Moxa VPort 36-1MP.
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes
dictating the maximum current allowable for each wire size.
If the current goes above the maximu
m ratings, the wiring could overheat, causing serious damage to your
equipment.
You should also pay attention to the following:
Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must
cross make sure the wires are perpendicular at the intersection point.
NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid
interference, wires with different signal characteristics should be routed separately.
You can use the type of signal transmitted through a wire to determine which wires should be kept separate.
The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
Keep input wiring and output wiring separated.
We strongly advise labeling the wiring to all devices in the system.