Moxa VPort 36-1MP-IVA [44/78] Modbus tcp

Moxa VPort 36-1MP-IVA-T [44/78] Modbus tcp
VPort 36-1MP System Configuration
4-23
Trap Settings
Setting Description Default
Trap Server
IP/Name
Enter the IP address or name of the Trap Server used by
your
network.
No
Trap Community Use a community string match for authentication; Maximum of
30 characters.
No
Private MIB information
The private SNMP Object ID of the VPort is the enterprise value: 8691.8.4.2. This number cannot be changed.
NOTE
The MIB file is MOXA
-VPORT16-
MIB.mib (or.my). You can find it on the software CD or the download center of
the Moxa website.
Modbus/TCP
Modbus is a serial communications protocol that is often used to connect a supervisory computer with a remote
terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems. To transmit Modbus over a
TCP/IP network, a standard Modbus/TCP protocol is provided. With the support of the Modbus/TCP protocol,
the SCADA/HMI system can directly communicate with the VPort to acquire its operational status.
Setting Description Factory Default
Enable Modbus/TCP Enable the Modbus/TCP protocol Enable
IEEE 802.1X
IEEE 802.1X is a network security protocol for authenticating devices wishing to connect to a LAN or WLAN.
Setting Description Default
Enable 802.1X Enable/Disable 802.1X function No
EAP Method Choose Authentication method EAP-MD5
Username Set username Blank
Password Ser password Blank