D-Link DWS-3160-24TC [243/983] Restrictions

D-Link DWS-3160-24TC [243/983] Restrictions
DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
239
md_index(Optional) Specifies the maintenance domain index.
<uint 1-4294967295> - Enter the maintenance domain index value here. This value must
between 1 and 4294967295.
ma - Specifies the maintenance association name.
<string 22> - Enter the maintenance association name here. This name can be up to 22
characters long.
ma_index(Optional) Specifies the maintenance association index.
<uint 1-4294967295> - Enter the maintenance association index value here. This value must
between 1 and 4294967295.
mepid - The MEP ID in the MD which sends LCK frame.
<int 1-8191> - Enter the MEP ID value here. This value must be between 1 and 8191.
period - (Optional) The transmitting interval of LCK PDU. The default period is 1 second.
1sec - Specifies that the transmitting interval will be set to 1 second.
1min - Specifies that the transmitting interval will be set to 1 minute.
level - (Optional) The client level ID to which the MEP sends LCK PDU. The default client MD
level is MD level at which the most immediate client layer MIPs and MEPs exist.
<int 0-7> - Enter the client level ID here. This value must be between 0 and 7.
state - (Optional) Specifies to enable or disable the LCK function.
enable - Specifies that the LCK function will be enabled.
disable
- Specifies that the LCK function will be disabled.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To configure the LCK function enabled and client level is 5:
DWS-3160-24PC:admin# config cfm lock md op-domain ma op-ma mepid 1 state enable
level 5
Command: config cfm lock md op-domain ma op-ma mepid 1 state enable level 5
Success.
DWS-3160-24PC:admin#
20-3 cfm lock md
Description
This command is used to start/stop cfm management lock. This command will result in the MEP
sends a LCK PDU to client level MEP.
Format
cfm lock md [<string 22> | md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint
1-4294967295>] mepid <int 1-8191> remote_mepid <int 1-8191> action [start | stop]
Parameters
md - Specifies the maintenance domain name.
<string 22> - Enter the maintenance domain name here. This name can be up to 22
characters long.
md_index(Optional) Specifies the maintenance domain index.

Содержание

Похожие устройства

Скачать