D-Link DWS-3160-24TC [600/983] Parameters

D-Link DWS-3160-24TC [600/983] Parameters
DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
596
Parameters
analyzer_server - The ID of analyzer server that to be deleted.
<value 1-4> - Enter the analyzer server ID value here. This value must be between 1 and 4.
Restrictions
Only Administrators and Operators can issue this command.
Example
To delete an analyzer server:
DWS-3160-24PC:admin# delete sflow analyzer_server 1
Command: delete sflow analyzer_server 1
Success.
DWS-3160-24PC:admin#
64-10 enable sflow
Description
This command is used to enable the sFlow function on the Switch.
Format
enable sflow
Parameters
None.
Restrictions
Only Administrators and Operators can issue this command.
Example
To enable sFlow globally:
DWS-3160-24PC:admin# enable sflow
Command: enable sflow
Success.
DWS-3160-24PC:admin#

Содержание

Похожие устройства

Скачать